Lightolier Lighting Systems Baselyte-BSL14, Page of, Light T5 HO Semi-Indirect, Performance

Models: Baselyte-BSL14

1 7
Download 7 pages 58.31 Kb
Page 2
Image 2
Lighting Systems  Baselyte-BSL14

Lighting SystemsBaselyte-BSL14

Page of 7

Performance

Candlepower Curve

 







 

 

 

 

 

 

 



 

 

 

 

 

 

 

 



 

 

 

 



 

 

 

 



 

 

 

 



 

 

 

 



 

 

 

 





 

 

 





 

 

 



 

 

 

 

 

 

 

 





 

 

 



 

 

 

 



 

 

 



 

 





 





 

 

 

 

Report No: 9900245

Lamps: F54T54

Lumens per Lamp: 4650

Efficiency: 92.9%

Up: 98.8% Down: 1.2%

Candlepower Summary

ZONE

 

CANDLEPOWER

 

DEG.

0

22.5

45

67.5

90

180

1073

1073

1073

1073

1073

175

1067

1069

1072

1074

1075

165

1027

1036

1054

1069

1074

155

954

974

1016

1053

1066

145

848

885

960

1028

1051

135

713

774

894

1005

1042

125

553

648

844

1042

1084

115

380

533

826

881

922

105

198

457

583

628

661

95

43

126

67

27

28

90

2

3

5

6

7

85

4

4

5

6

6

75

5

6

6

7

7

65

5

7

9

10

10

55

6

8

10

12

12

45

8

9

11

12

13

35

10

10

13

13

13

25

11

12

13

14

14

15

12

12

13

14

14

5

12

12

12

13

12

0

12

12

12

12

12

Light T5 HO Semi-Indirect

Coefficients of Utilization

 

 

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

 

80

 

 

70

 

 

 

50

 

 

 

 

 

% WALL REFLECTANCE

 

 

 

 

50

30

10

50

30

10

 

50

30

10

0

88

88

88

75

75

75

 

52

52

52

1

76

73

70

65

63

60

 

45

43

42

2

66

61

57

57

53

49

 

39

37

34

3

58

52

47

50

45

41

 

34

31

29

4

51

44

39

44

38

34

 

30

27

24

5

45

38

33

39

33

29

 

27

23

20

6

40

33

28

34

29

25

 

24

20

17

7

36

29

24

31

25

21

 

21

18

15

8

32

26

21

28

22

18

 

19

16

13

9

29

23

18

25

20

16

 

17

14

11

10

26

20

16

23

18

14

 

16

12

10

Zonal Lumen Summary

 

ZONE

LUMENS

%BARE LAMP

%LUMINAIRE

0-90

53.5

1.2

1.2

90-180

4267.5

91.8

98.8

0-180

4321

92.9

100.0

Module Lengths & Mounting Distances

@

-ODULE ,ENGTH ,

-OUNTING $ISTANCE

@

-ODULE ,ENGTH ,-OUNTING $ISTANCE

@

-ODULE ,ENGTH ,-OUNTING $ISTANCE

Note: Shaded area indicates locations of emergency sections (emergency wiring controls all lamps or optional battery pack controls one or two lamps).

Run Configuration

Run

4’

8’

12’

Joiner

End Set

Mount

Power

Length

Module

Module

Module

Mount*

 

 

 

 

 

 

 

 

 

 

 

4’ run

1

 

 

 

1

1

1

 

 

 

 

 

 

 

 

8’ run

 

1

 

 

1

1

1

 

 

 

 

 

 

 

 

12’ run

 

 

1

 

1

1

1

 

 

 

 

 

 

 

 

16’ run

 

2

 

1

1

2

1

 

 

 

 

 

 

 

 

20’ run

 

1

1

1

1

2

1

 

 

 

 

 

 

 

 

24’ run

 

 

2

1

1

2

1

 

 

 

 

 

 

 

 

28’ run

 

2

1

2

1

3

1

 

 

 

 

 

 

 

 

32’ run

 

1

2

2

1

3

1

 

 

 

 

 

 

 

 

*Note: Additional power mounts may be required for some runs with T5 HO lamping options, longer runs, and runs with wiring options that are more complex. Please consult factory for assistance.

System Components & Accessories
End Set

BSLESW = suspended standard white

Joiner

BSLJS = suspended joiner

Job Information

Type:

Lightolier a Genlyte Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.1

Page 2
Image 2
Lightolier Lighting Systems Baselyte-BSL14, Page of, Light T5 HO Semi-Indirect, Performance, Run Configuration, Type