Performance

 

 

 

 

 

 

 

Candlepower Curve

Candlepower Summary

 

 

 







 

 

ZONE

 

CANDLEPOWER

 

 

 

 

 

 

 

 

 

 

DEG.

0

22.5

45

67.5

90

 

 

 



 

 

 

 

 

 

 

 



 

 

180

3199

3199

3199

3199

3199

 

 

 



 

175

3184

3183

3190

3201

3204

 

 

 



165

3072

3089

3135

3155

3165

 

 

 



155

2858

2901

2961

3016

3042

 

 

 



145

2551

2605

2731

2843

2889

 

 

 

 



135

2165

2236

2450

2663

2747

 

 

 

 

 

125

1714

1818

2174

2470

2571



 

 



115

1214

1390

1865

2056

2128



 

 



105

657

975

1266

1342

1404

 

 

 

 

95

154

302

387

341

367

 

 

 



 



 

 



 

90

5

13

30

46

55

 

 

 



 

85

11

16

31

49

56



 

 

 

 

75

19

25

47

67

75

 

 

 



 

 

 

 



 

 

 

 

 

 

 

 





 

 

65

26

40

65

84

92

 

 

 

 

 

55

41

58

81

99

107

Report No: 9900159

45

64

75

94

111

118

35

88

92

109

119

125

Lamps: F54T5

25

109

110

120

127

131

Lumens per Lamp: 4650

15

123

123

126

131

133

Efficiency: 84.9%

5

131

131

131

131

131

Up: 96.1% Down: 3.9%

0

132

132

132

132

132

Module Lengths & Mounting Distances

@

-ODULE ,ENGTH ,

-OUNTING $ISTANCE

@

-ODULE ,ENGTH ,-OUNTING $ISTANCE

@

-ODULE ,ENGTH ,-OUNTING $ISTANCE

Note: Shaded area indicates locations of emergency sections (emergency wiring controls all lamps or optional battery pack controls one or two lamps).

3 Light T5 HO Semi-Indirect

Coefficients of Utilization

 

 

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

 

80

 

 

70

 

 

 

50

 

 

 

 

 

% WALL REFLECTANCE

 

 

 

 

50

30

10

50

30

10

 

50

30

10

0

81

81

81

70

70

70

 

49

49

49

1

70

67

64

60

58

56

 

42

41

39

2

61

56

52

53

49

45

 

37

34

32

3

54

48

43

46

41

38

 

32

29

27

4

47

41

36

41

36

32

 

28

25

23

5

42

35

31

36

31

27

 

25

22

19

6

37

31

26

32

27

23

 

22

19

16

7

33

27

22

29

23

20

 

20

17

14

8

30

24

19

26

21

17

 

18

15

12

9

27

21

17

23

18

15

 

16

13

11

10

24

19

15

21

16

13

 

15

12

9

Zonal Lumen Summary

 

ZONE

LUMENS

%BARE LAMP

%LUMINAIRE

0-90

461

3.3

3.9

90-180

11380

81.6

96.1

0-180

11841

84.9

100.0

Run Configuration

Run

4’

8’

12’

Joiner

End Set

Mount

Power

Length

Module

Module

Module

Mount*

 

 

 

 

 

 

 

 

 

 

 

4’ run

1

 

 

 

1

1

1

 

 

 

 

 

 

 

 

8’ run

 

1

 

 

1

1

1

 

 

 

 

 

 

 

 

12’ run

 

 

1

 

1

1

1

 

 

 

 

 

 

 

 

16’ run

 

2

 

1

1

2

1

 

 

 

 

 

 

 

 

20’ run

 

1

1

1

1

2

1

 

 

 

 

 

 

 

 

24’ run

 

 

2

1

1

2

1

 

 

 

 

 

 

 

 

28’ run

 

2

1

2

1

3

1

 

 

 

 

 

 

 

 

32’ run

 

1

2

2

1

3

1

 

 

 

 

 

 

 

 

*Note: Additional power mounts may be required for some runs with T5 HO lamping options, longer runs, and runs with wiring options that are more complex. Please consult factory for assistance.

System Components & Accessories
End Set

BSLESW = suspended standard white

Joiner

BSLJS = suspended joiner

Job Information

Type:

Lightolier a Genlyte Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.1

Page 2
Image 2
Lightolier Lighting Systems Baselyte-BSL16, Light T5 HO Semi-Indirect, Page, Performance, Run Configuration, Type