Lighting SystemsBaselyte-BSL31

Page of 4

 Light T5 HO Wall Mount Indirect

Performance

Candlepower Curve











 

 

 

 

 



 

 

 



 

 

 

 

 

 

 

 

 

 

 

 

 

 



 

 

 

 

 



 

 

 

 

 



 

 

 

 

 



 

 

 

 

 



 

 

 

 

 



 



 

 

 



 

 

 

 

 

 



 

 

 



 



 

 

 



 

 

 

 



 

 

 

 

 

 



 

 

 



 

 

 

 

 



 

 

 

 











 

 

 

 

Report No: 2101686

Lamps: F54T5

Lumens per Lamp: 4650

Efficiency: 58.3%

Up: 100.0% Down: 0.0%

Candlepower Summary

 

 

 

Coefficients of Utilization

 

 

 

 

 

 

 

ZONE

 

CANDLEPOWER

 

 

 

 

 

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

 

 

 

 

 

 

 

 

DEG.

0

45

90

135

180

 

 

 

 

80

 

 

 

70

 

 

 

50

 

 

180

464

464

464

464

464

 

 

 

 

 

 

 

% WALL REFLECTANCE

 

 

175

531

511

461

414

390

 

 

 

50

30

10

 

50

30

10

 

50

30

10

165

658

596

447

311

261

 

0

 

55

55

55

 

47

47

47

 

32

32

32

155

825

665

419

235

245

1

 

48

46

44

 

41

39

38

 

28

27

26

145

1019

781

378

222

229

2

 

42

38

36

 

35

33

31

 

24

23

21

135

1203

878

328

201

207

3

 

36

32

29

 

31

28

25

 

21

19

18

4

 

32

28

25

 

27

24

21

 

19

17

15

125

1409

977

268

172

172

 

 

 

5

 

28

24

21

 

24

21

18

 

16

14

13

115

1588

1048

199

133

133

 

 

 

6

 

25

21

18

 

21

18

15

 

15

12

11

105

977

1012

116

90

85

 

 

 

7

 

22

18

15

 

19

16

13

 

13

11

9

95

237

244

31

33

36

 

 

 

8

 

20

16

13

 

17

14

11

 

12

10

8

90

39

18

2

6

7

 

 

 

9

 

18

14

11

 

16

12

10

 

11

8

7

85

0

0

0

0

0

 

 

 

10

 

16

13

10

 

14

11

9

 

10

7

6

75

0

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

0

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55

0

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

0

0

0

0

0

Zonal Lumen Summary

 

 

 

 

 

 

35

0

0

0

0

0

ZONE

 

LUMENS

 

 

%BARE LAMP

 

%LUMINAIRE

 

25

0

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

0

0

0

0

0

0-90

 

0

 

0

 

 

0

 

 

5

0

0

0

0

0

90-180

2709

 

58.3

 

 

100.0

 

 

0

0

0

0

0

0

0-180

 

2709

 

58.3

 

 

100.0

 

 

Module Lengths & Mounting Distances

@

-ODULE ,ENGTH ,

-OUNTING $ISTANCE

@

-ODULE ,ENGTH ,-OUNTING $ISTANCE

@

-ODULE ,ENGTH ,-OUNTING $ISTANCE

Note: Shaded area indicates locations of emergency sections (emergency wiring controls all lamps or optional battery pack controls one or two lamps).

Run Configuration

Run

4’

8’

12’

Joiner

End Set

Mount

Power

Length

Module

Module

Module

Mount*

 

 

 

 

 

 

 

 

 

 

 

4’ run

1

 

 

 

1

1

1

 

 

 

 

 

 

 

 

8’ run

 

1

 

 

1

1

1

 

 

 

 

 

 

 

 

12’ run

 

 

1

 

1

1

1

 

 

 

 

 

 

 

 

16’ run

 

2

 

1

1

2

1

 

 

 

 

 

 

 

 

20’ run

 

1

1

1

1

2

1

 

 

 

 

 

 

 

 

24’ run

 

 

2

1

1

2

1

 

 

 

 

 

 

 

 

28’ run

 

2

1

2

1

3

1

 

 

 

 

 

 

 

 

32’ run

 

1

2

2

1

3

1

 

 

 

 

 

 

 

 

*Note: Additional power mounts may be required for some runs with T5 HO lamping options, longer runs, and runs with wiring options that are more complex. Please consult factory for assistance.

System Components & Accessories

End Set

BSLEWW = wall mount standard white

Joiner

BSLJW = wall mount joiner

Non-Power Wall Mount

 

Power Wall Mount

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BSLWN = non-power wall mount

BSLWP1 = 1-power mount

 

BSLWP2 = 2-power mount

Job Information

Type:

Lightolier a Genlyte Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.1

Page 2
Image 2
Lightolier Baselyte-BSL31 specifications Performance, Module Lengths & Mounting Distances, Run Configuration