Lighting Systems Baselyte-BSL5
Page of 8
Wiring Options: 1 Circuit
1 Circuit
Type 1: 1cct.
Type 8: 1cct. w/1cct. thru wire
Type H: 1cct. w/2cct. thru wire
Type 7: 1cct. w/dimming
2 Light T5 HO Direct/Indirect
All lamps wired on one circuit.
1 Circuit with Emergency Circuit/Night Light (EC/NL)
Type 3: 1cct. w/EC/NL
%#., | ||
%#., |
One 4’ section in a one circuit fixture to be wired on a separate thru circuit. Leads for both normal circuit and EC/NL circuit wired to fixture ends. All lamps in EC/NL section to be wired together.
1 Circuit with Emergency Battery Pack (EM)
Type 5: Chloride standard
CTP700
Type M: Bodine standard
LP550
Type E: Chloride high performance
CTP1300
Type P: Bodine high performance
LP600
� | � | %- |
� | � | � |
All lamps wired on one circuit, plus a battery pack is wired to one lamp. A hot lead is connected to the battery pack and would function as a ‘trigger’ wire when connected to a constant hot by installer. Leads for both normal circuit and battery pack are wired to fixture ends.
*Note:
1 Circuit with Emergency Circuit/Night Light and Emergency Battery Pack
Type J: Chloride standard CTP700
%#., | ||
%#.,%- |
One 4’ section in a one circuit fixture to be wired on a separate thru circuit, in addition, a battery pack is wired to one lamp. Installer can connect ‘trigger’ wire to EC hot lead if controlled together or wire separately if controlled independently. Leads for normal circuit and EM wired to fixture ends. All lamps in EC/NL section to be wired together.
*Note:
Job Information | Type: |
Lightolier a Genlyte Company | www.lightolier.com |
631 Airport Road, Fall River, MA 02720 • (508)
© 2005 Genlyte Group LLC • 0205 Rev.1