C2 Series Emergency Lighting C2

Page 1 of 2 6 or 12 Volt 14 to 50 Watts Thermoplastic Housing

Lightolier is a Philips group brand

Features
1. Illuminatio n: Allows up to f our mounted lamp heads. The stan dard head
incorporates a high pe rformance p arabolic reflec tor with a wedg e base
tungsten lamp. Allows ma ximum spacing bet ween units alo ng a path of
egress.
2. Housing: Cons tructed of 18 gauge steel wit h a white epox y powder coat
finish. Designed for easy drop-in installatio n into suspended ceilings.
3. Electroni cs: 120/277 VAC dual volta ge input with su rge-protect ed, solid-
state circuitry. Charg ing system is co mplete with low voltage disconn ect, AC
lockout, brownout p rotection, AC indi cator lamp and t est switch.
4. Batter y: Maintenance f ree, sealed lead calcium batter y has an estim ated
service life of 5 yea rs, and an operat ing temperatur e range of 65°F (19°C)
to 85°F (30°C). Maintenan ce free, sealed ni ckel cadmium bat tery has an
estimated service life of 10 years, and an operating te mperature ran ge of
20°F (-7°C) to 95°F (35°C).
5. Input Powe r Requiremen ts: 120 VAC - 0.18 amps, 20 wat ts;
277 VAC - 0.08 amps, 20 wat ts
Code Compliance
UL 924 listed.
Options
SD = Self-Diagnostics
SA = Self-Diagnostics with Ala rm
T1 = 120 VAC Time Delay
T2 = 277 VAC Time Delay
V = Voltmeter
A = Ammeter
F1 = 120 VAC Fuse
F2 = 277 VAC Fuse
P1 = 120 VAC Power Switch
P2 = 277 VAC Power Switch
Multiple option conf igurations may void UL lis ting. Cons ult factor y for spe cifics.
How to Specify:
SER IES DC VOLTAGE BATTERY # OF LAMP
HEADS HEADS
C2
C2 = Recessed
Emergency Lighting
Unit
6V Round Wedge Base
RT6 = 5.4W Tungsten
RT7 = 7.2W Tungsten
RT9 = 9W Tungsten
RH7 = 7W Halogen
RH10 = 10W Halogen
RH12 = 12W Halogen
12V Round Wedge Base
RT9 = 9W Tungsten
RT12 = 12.5W Tungsten
RT18 = 17.9W Tungsten
RH12 = 12W Halogen
4 = Four
3 = Three
2 = Two
1 = One
Blank = No Lamp Heads
1 = 6 volt
2 = 12 volt
6V, Lead Calcium
25L = 25W Unit
50L = 50W Unit
6V, Nickel Cadmium
14N = 14W Unit
25N = 25W Unit
12V, Lead Calcium
50L = 50W Unit
12V, Nickel Cadmium
25N = 25W Unit
50N = 50W Unit
12.0”
(30.5 cm)
17”
(43.2 cm)
5.8”
(14.7 cm)
24.0”
(61.0 cm)
Recessed depth is 4.3” 6.0”
(15.2 cm)
For additional lamp heads, see
RT66 Specifica tion Sheet
The C2 Series provides low profile, recessed emergency lighting for commercial interiors. It is also available as a master unit for remote operation.