Calculite® HID Downlight C6T6VN

Page 2 of 2 6" Aperture, 2pc Vertical, T6 Narrow Beam

CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .76 .76 .76 .76 .74 .74 .71 .71 .68 .68 .64
1 .73 .72 .71 .70 .71 .68 .68 .66 .66 .64 .61
2 .71 .68 .66 .65 .67 .64 .65 .63 .63 .61 .59
3 .68 .65 .63 .61 .64 .60 .63 .59 .61 .58 .57
4 .66 .62 .59 .57 .61 .57 .60 .56 .59 .56 .54
5 .63 .59 .56 .54 .59 .54 .57 .53 .57 .53 .52
6 .61 .57 .54 .52 .56 .51 .55 .51 .55 .51 .50
7 .59 .54 .51 .49 .54 .49 .53 .49 .52 .48 .47
8 .57 .52 .49 .47 .51 .46 .51 .46 .50 .46 .45
9 .54 .49 .46 .44 .49 .44 .48 .44 .48 .44 .43
10 .52 .47 .44 .42 .47 .42 .46 .42 .46 .42 .41
LUMINAIRE INPUT WATTS = 44
ANGLE MEAN CP LUMENS
0 3984
5 3765 352
10 3218
15 2533 716
20 1816
25 1212 583
30 795
35 570 368
40 407
45 189 155
50 14
55 2 4
60 0
65 0 0
70 0
75 1 1
80 0
85 0 0
90 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 1650 48.53 75.77
0-40 2017 59.35 92.67
0-60 2176 64.02 99.96
0-90 2177 64.05 100.00
40-90 159 4.70 7.33
60-90 0 .02 .04
90-180 0 .00 .00
0-180 2177 64.05 100.00
39W T6 PHILIPS METAL HALIDE LAMP. LUMEN RATING = 3400 LMS. AROMAT ELECTRONIC BALLAST, CL Finish
Coefficients of Utilization
LUMINANCE SUMMARY
CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 16034
55 175
65 0
75 162
85 0
** EFFICIENCY = 64.0% ** CERTIFIED TEST REPORT NO. 2336FR, DATE: OCT 24, 2003
SC = 0.6 COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .75 .75 .75 .75 .73 .73 .70 .70 .67 .67 .63
1 .72 .71 .69 .68 .70 .67 .67 .65 .64 .63 .60
2 .69 .67 .65 .63 .66 .63 .64 .61 .62 .60 .58
3 .67 .64 .61 .59 .63 .59 .61 .58 .60 .57 .55
4 .64 .61 .58 .56 .60 .56 .59 .55 .58 .54 .53
5 .62 .58 .55 .53 .57 .52 .56 .52 .55 .52 .50
6 .60 .55 .52 .50 .55 .50 .54 .50 .53 .49 .48
7 .57 .53 .50 .48 .52 .47 .51 .47 .51 .47 .46
8 .55 .50 .47 .45 .50 .45 .49 .45 .49 .45 .44
9 .53 .48 .45 .43 .47 .43 .47 .42 .46 .42 .41
10 .51 .46 .43 .40 .45 .40 .45 .40 .44 .40 .39
LUMINAIRE INPUT WATTS = 78
ANGLE MEAN CP LUMENS
0 7054
5 6730 630
10 5887
15 4740 1334
20 3463
25 2357 1129
30 1584
35 1148 737
40 812
45 377 310
50 33
55 7 11
60 4
65 2 2
70 0
75 0 0
80 0
85 0 0
90 0
70W T6 PHILIPS METAL HALIDE LAMP. LUMEN RATING = 6600 LMS. AROMAT ELECTRONIC BALLAST, CL Finish
Coefficients of Utilization
LUMINANCE SUMMARY
CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 31949
55 688
65 350
75 0
85 0
** EFFICIENCY = 62.9% ** CERTIFIED TEST REPORT NO. 2334FR, DATE: OCT 14, 2003
SC = 0.6 COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 3093 46.88 74.48
0-40 3830 58.04 92.22
0-60 4151 62.91 99.95
0-90 4153 62.94 100.00
40-90 323 4.89 7.78
60-90 2 .03 .05
90-180 0 .00 .00
0-180 4153 62.94 100.00
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .73 .73 .73 .73 .71 .71 .68 .68 .65 .65 .61
1 .70 .69 .67 .66 .68 .65 .65 .63 .63 .61 .59
2 .67 .65 .63 .61 .64 .61 .62 .59 .60 .58 .56
3 .65 .62 .59 .57 .61 .57 .59 .56 .58 .55 .54
4 .62 .59 .56 .54 .58 .54 .57 .53 .56 .53 .51
5 .60 .56 .53 .51 .55 .51 .54 .50 .53 .50 .49
6 .58 .53 .50 .48 .53 .48 .52 .48 .51 .47 .46
7 .55 .51 .48 .46 .50 .45 .50 .45 .49 .45 .44
8 .53 .48 .45 .43 .48 .43 .47 .43 .47 .43 .42
9 .51 .46 .43 .41 .46 .41 .45 .41 .45 .40 .40
10 .49 .44 .41 .39 .43 .39 .43 .38 .43 .38 .38
LUMINAIRE INPUT WATTS = 167
ANGLE MEAN CP LUMENS
0 13758
5 13134 1232
10 11593
15 9424 2655
20 7028
25 4935 2359
30 3491
35 2551 1627
40 1766
45 816 671
50 70
55 12 22
60 4
65 7 5
70 3
75 1 2
80 0
85 0 0
90 0
150W T6 PHILIPS METAL HALIDE LAMP. LUMEN RATING = 14000 LMS. AROMAT ELECTRONIC BALLAST, CL Finish
15000
7500
Coefficients of Utilization
LUMINANCE SUMMARY
CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 69119
55 1223
65 1001
75 344
85 0
** EFFICIENCY = 61.2% ** CERTIFIED TEST REPORT NO. 2333FR, DATE: OCT 13, 2003
SC = 0.7 COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 6246 44.62 72.86
0-40 7873 56.24 91.83
0-60 8566 61.19 99.92
0-90 8573 61.24 100.00
40-90 700 5.00 8.17
60-90 6 .05 .08
90-180 0 .00 .00
0-180 8573 61.24 100.00
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
2,000
3,500
15,000
30°
60°
30°
60°
30°
60°
1,000
3,000
4,000
1,750
5,250
7,000
7,500
3,750
11,250