| 7” Aperture, ED17 (Open Rated) Ceramic Metal Halide | |||||
| 20" (508 mm) to 30" (762 mm) | 8 | 6 | 2 | 1 | 4 5 3 8 | 9 | 7 | |
| |||||||||
| (210 mm) | (248 mm) |
|
|
|
|
|
|
|
5/8" (473 mm) |
|
|
|
|
|
|
| ||
18- |
|
|
|
|
|
|
|
|
|
| Top View |
|
|
|
|
|
|
| |
| (Magnetic Ballast) |
|
|
|
|
|
| ||
| 20" (508 mm) to | (251 mm) |
|
|
|
|
|
| |
|
|
|
|
|
|
|
| ||
| 30" (762 mm) |
|
|
|
|
|
| Vertical Adjustment: | |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| 5/8" (16 mm) to | |
|
| (248 mm) |
|
|
|
|
|
| |
|
|
|
|
|
|
|
| 2 7/8" (73 mm) | |
|
|
|
|
|
|
|
|
| |
|
| 11" (280 mm) |
|
|
|
|
|
|
|
|
| (100/150W) |
|
|
|
|
|
|
|
Top View
(Electronic Ballast)
2" (50 mm) max. Ceiling Thickness
Ceiling Cutout: 8” (203mm) Dia.
Reflector Trim |
|
| Lamp (Coated, Ceramic MH) | |||
C7E17OW CLW | Specular Clear, White Painted Flange. | C770MHOE1 Electronic 120V / C770MHOE2 Electronic 277V | 70W E17, ED17, BD17 (Open Rated) | |||
| CLP | Specular Clear, Matching Flange. | C710MHOE1 Electronic 120V / C710MHOE2 Electronic 277V | 100W E17, ED17, BD17 (Open Rated) | ||
| CCDW | Comfort Clear Diffuse, White Painted Flange. | C715MHOE1 Electronic 120V / C715MHOE2 Electronic 277V | 150W E17, ED17, BD17 (Open Rated) | ||
| CCDP | Comfort Clear Diffuse, Matching Flange. | C770MHOU | Magnetic 120V/277V | 70W E17, ED17, BD17 (Open Rated) | |
| CCZW | Champagne Bronze, White Painted Flange. | C710MHOU | Magnetic 120V/277V | 100W E17, ED17, BD17 (Open Rated) | |
| CCZP | Champagne Bronze, Matching Flange. | C715MHOU | Magnetic 120V/277V | 150W E17, ED17, BD17 (Open Rated) | |
|
|
|
|
|
|
|
Features
1.Downlight/Wall Washer Reflector Trim: Anodized aluminum, 0.040” (16- ga.). Provides vertical surface wall washing and medium beam downlighting; 50° visual
2.Socket Housing: Galvanized steel,
3.Mounting Frame: 0.048"
4.Mounting Ring: 0.048"
5.Retention Springs: Rust resistant springs secure reflector in place for quick,
6.Frame Vertical Adjustment Mechanism: Vertical adjustment mechanism accommodates mounting to virtually any ceiling system using
7.Mounting Bars: 0.048"
8.Ballast: Electronic 120V or 277V. Magnetic dual voltage (120V & 277V). Accessible from below for inspection and/or replacement without tools.
9.Junction Box: 0.059"
10.Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire.
Electrical
Electronic Ballast: 120V or 277V, 50/60 Hz., encased,
Electrical (cont)
Ballast | ANSI Code | Voltage | Max. Amps | Input Watts |
70W MH | M98/M143 | 120/277 | 0.67/0.28 | 78 |
100W MH | M90/M140 | 120/277 | 0.90/0.43 | 110 |
150W MH | M102 | 120/277 | 1.40/0.61 | 167 |
Magnetic Ballast: 120V/277V dual voltage, 60 Hz., encased and potted,
Ballast | ANSI Code | Voltage | Max. Amps | Input Watts |
70W MH | M98/M143 | 120/277 | 1.90/0.80 | 94 |
100W MH | M90/M140 | 120/277 | 2.40/1.10 | 125 |
150W MH | M102 | 120/277 | 3.70/1.60 | 180 |
Options and Accessories
Fuse: Add suffix F1 or F2 to
Chicago Plenum: Consult Factory.
Labels
UL (Suitable for Damp Locations), I.B.E.W.
For 150W, install fixtures with minimum spacing between:
1.
2.Top of luminaire to overhead building member: 3 inch.
3.Luminaire center to side building member: 1 1/2 feet.
Job Information | Type: |
|
|
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte companywww.lightolier.com 631 Airport Road, Fall River, MA 02720 • (508)
© 2004 Genlyte Group LLC • B1004