| Calculite® HID Downlight C9E28VN |
Page 2 of 2 | 9" Aperture, ED28 (Enclosed), Metal Halide, Narrow Beam |
175W ED28, PHILIPS MH COATED LAMP, LUMEN RATING = 12900 LMS, ADVANCE MAGNETIC BALLAST, CL FINISH TRIM
CANDLEPOWER DISTRIBUTION
2,250
4,500
6,750
9,000
| ANGLE | MEAN CP | LUMENS |
| 0 | 9482 |
|
| 5 | 8632 | 809 |
| 10 | 7160 |
|
| 15 | 6075 | 1726 |
| 20 | 5041 |
|
60° | 25 | 3948 | 1829 |
30 | 2866 |
| |
|
| ||
| 35 | 1919 | 1239 |
| 40 | 1185 |
|
| 45 | 666 | 530 |
| 50 | 218 |
|
| 55 | 23 | 60 |
| 60 | 3 |
|
| 65 | 1 | 1 |
| 70 | 0 |
|
| 75 | 0 | 0 |
| 80 | 0 |
|
| 85 | 0 | 0 |
30° | 90 | 0 |
|
|
|
|
LUMINANCE SUMMARY CD. / SQ. M. |
|
|
|
|
|
| Coefficients of Utilization |
|
|
|
| |||||||
ANGLE | MEAN CD/SQ M |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
45 |
| 23031 |
| CEILING |
|
| 80% |
|
| 70% |
| 50% |
| 30% |
|
| ||
|
|
|
|
|
|
|
|
|
| |||||||||
55 |
| 988 |
|
|
|
|
|
|
|
|
| |||||||
|
|
| WALL | 70 | 50 | 30 | 10 | 50 | 10 | 50 | 10 | 50 | 10 | 0 |
| |||
65 |
| 78 |
|
|
| |||||||||||||
75 |
| 32 |
|
|
| RCR | Zonal Cavity Method | - Effective | Floor Cavity | Reflectance | = 20% | |||||||
85 |
| 0 |
|
| 0 | .57 | .57 | .57 | .57 | .56 | .56 | .53 | .53 | .51 | .51 | .48 |
| |
|
|
|
|
| 1 | .55 | .54 | .53 | .52 | .53 | .51 | .51 | .49 | .49 | .48 | .46 |
| |
|
|
|
|
|
| 2 | .53 | .51 | .49 | .48 | .50 | .47 | .48 | .46 | .47 | .45 | .44 |
|
ZONAL LUMENS AND PERCENTAGES |
| 3 | .51 | .48 | .46 | .45 | .47 | .44 | .46 | .44 | .45 | .43 | .42 |
| ||||
| 4 | .49 | .46 | .44 | .42 | .45 | .42 | .44 | .41 | .43 | .41 | .40 |
| |||||
ZONE LUMENS | % LAMP %LUMINAIRE |
|
| |||||||||||||||
4363 | 33.82 | 70.45 |
| 5 | .47 | .43 | .41 | .39 | .43 | .39 | .42 | .39 | .41 | .38 | .37 |
| ||
5602 | 43.43 | 90.45 |
| 6 | .45 | .41 | .39 | .37 | .41 | .37 | .40 | .37 | .40 | .36 | .36 |
| ||
6191 | 48 | 99.97 |
| 7 | .43 | .39 | .37 | .35 | .39 | .35 | .38 | .35 | .38 | .34 | .34 |
| ||
6193 | 48.01 | 100.00 |
| 8 | .41 | .37 | .35 | .33 | .37 | .33 | .36 | .33 | .36 | .32 | .32 |
| ||
591 | 4.58 | 9.55 |
| 9 | .39 | .35 | .33 | .31 | .35 | .31 | .34 | .31 | .34 | .31 | .30 |
| ||
1 | 0.01 | 0.03 |
|
| ||||||||||||||
| 10 | .37 | .33 | .31 | .29 | .33 | .29 | .33 | .29 | .32 | .29 | .28 |
| |||||
0 | 0 | 0 |
|
| ||||||||||||||
6193 | 48.01 | 100.00 |
|
|
|
| LUMINAIRE INPUT WATTS = 205 |
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
** EFFICIENCY = 48.0% **
CERTIFIED TEST REPORT NO. 2450FR, DATE: FEB 12, 2004
SC = .6 COMPUTED BY LSI PROGRAM
250W ED28, PHILIPS MH COATED LAMP, LUMEN RATING = 19475 LMS, UNIVERSAL MAGNETIC BALLAST, CL FINISH TRIM
CANDLEPOWER DISTRIBUTION
6,000
12,000
| ANGLE | MEAN CP | LUMENS |
| 0 | 11750 |
|
| 5 | 11130 | 1042 |
| 10 | 9674 |
|
| 15 | 8222 | 2335 |
| 20 | 6835 |
|
60° | 25 | 5292 | 2464 |
| 30 | 3878 |
|
| 35 | 2612 | 1680 |
| 40 | 1598 |
|
| 45 | 900 | 716 |
| 50 | 299 |
|
| 55 | 23 | 77 |
| 60 | 0 |
|
| 65 | 0 | 0 |
| 70 | 0 |
|
| 75 | 0 | 0 |
| 80 | 0 |
|
| 85 | 0 | 0 |
30° | 90 | 0 |
|
|
|
|
LUMINANCE SUMMARY CD. / SQ. M. |
|
|
|
|
|
| Coefficients of Utilization |
|
|
|
|
|
| |||||||
ANGLE | MEAN CD/SQ M |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
45 |
| 31142 |
| CEILING |
|
| 80% |
|
| 70% |
| 50% |
| 30% |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
55 |
| 999 |
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
| WALL | 70 | 50 | 30 | 10 | 50 | 10 | 50 | 10 | 50 | 10 | 0 |
|
|
| |||
65 |
| 0 |
|
|
|
|
| |||||||||||||
75 |
| 0 |
|
|
| RCR | Zonal Cavity Method | - Effective | Floor Cavity | Reflectance | = 20% |
| ||||||||
85 |
| 0 |
|
| 0 | .51 | .51 | .51 | .51 | .50 | .50 | .47 | .47 | .45 | .45 | .43 |
|
|
| |
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
| 1 | .49 | .48 | .47 | .46 | .47 | .45 | .45 | .44 | .44 | .43 | .41 |
|
|
| |
|
|
|
|
|
| 2 | .47 | .45 | .44 | .43 | .44 | .42 | .43 | .41 | .42 | .40 | .39 |
|
|
|
ZONAL LUMENS AND PERCENTAGES |
| 3 | .45 | .43 | .41 | .40 | .42 | .39 | .41 | .39 | .40 | .38 | .37 |
|
|
| ||||
ZONE LUMENS | % LAMP %LUMINAIRE |
| 4 | .43 | .41 | .39 | .37 | .40 | .37 | .39 | .37 | .38 | .36 | .35 |
|
|
| |||
5842 | 30 | 70.25 |
| 5 | .41 | .39 | .36 | .35 | .38 | .35 | .37 | .34 | .37 | .34 | .33 |
|
|
| ||
7522 | 38.63 | 90.46 |
| 6 | .40 | .37 | .34 | .33 | .36 | .33 | .36 | .33 | .35 | .32 | .32 |
|
|
| ||
8315 | 42.7 | 100 |
| 7 | .38 | .35 | .32 | .31 | .34 | .31 | .34 | .31 | .33 | .30 | .30 |
|
|
| ||
8315 | 42.7 | 100 |
| 8 | .36 | .33 | .31 | .29 | .32 | .29 | .32 | .29 | .32 | .29 | .28 |
|
|
| ||
793 | 4.07 | 9.54 |
| 9 | .35 | .31 | .29 | .27 | .31 | .27 | .30 | .27 | .30 | .27 | .27 |
|
|
| ||
0 | 0 | 0 |
|
|
|
| ||||||||||||||
0 | 0 | 0 |
| 10 | .33 | .30 | .27 | .26 | .29 | .26 | .29 | .26 | .29 | .26 | .25 |
|
|
| ||
|
|
|
| |||||||||||||||||
8315 | 42.7 | 100 |
|
|
|
| LUMINAIRE INPUT WATTS = 290 |
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
** EFFICIENCY = 42.7% **
CERTIFIED TEST REPORT NO. 2460FR DATE:, FEB 19, 2004
SC = .7 COMPUTED BY LSI PROGRAM
Job Information |
| Type: |
Lightolier a Genlyte Thomas Company | www.lightolier.com |
631 Airport Road, Fall River, MA 02720 • (508)
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4