Lightolier CS7142 Page 2 of, Quick Calculator, Spacing Ratio =, Coefficients Of Utilization

Models: CS7142

1 2
Download 2 pages 2.37 Kb
Page 2
Image 2
Page 2 of 2

Calculite® Compact Fluorescent Surface Cylinder CS7142

Page 2 of 2

Quick Calculator

 

80

 

 

ROOM SURFACE REFLECTANCES:

 

 

 

 

80% Ceiling; 50% Wall; 20% Floor

 

70

 

 

2400 Lumens Per Lamp

 

 

 

 

60

 

 

RCR = 1 (Rm. width = 10 x Mtg. Ht. above work plane)

FOOTCANDLES

 

 

RCR = 5 (Rm. width = 2 x Mtg. Ht. above work plane)

 

 

 

50

 

 

RCR = 10 (Rm. width = Mtg. Ht. above work plane)

 

 

 

 

 

 

 

 

 

 

 

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INITIAL

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

40

60

80

100

120

 

 

 

AREA PER FIXTURE IN SQUARE FEET

 

 

3

4

5

6

7

8

9

10

11

CENTER TO CENTER DISTANCE OF FIXTURES IN FEET

This quick Calculator chart determines the number and spacing of 1 lt.-32W PL-T units with Comfort Clear™ reflector for any level of illumination. Conversion factor: 1 lt. 26W PL-T with Comfort Clear Clear™ reflector for any level of illumination. reflector, F.C. x 0.8.

7 3/8" Aperture Triple Tube (4-Pin) Ceiling & Wall Mount

Quick Calculator

 

80

 

 

 

ROOM SURFACE REFLECTANCES:

 

 

 

 

 

80% Ceiling; 50% Wall; 20% Floor

 

70

 

 

 

3200 Lumens Per Lamp

 

 

 

 

 

60

 

 

 

RCR = 1 (Rm. width = 10 x Mtg. Ht. above work plane)

FOOTCANDLES

 

 

 

RCR = 5 (Rm. width = 2 x Mtg. Ht. above work plane)

 

 

 

 

50

 

 

 

RCR = 10 (Rm. width = Mtg. Ht. above work plane)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INITIAL

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

40

60

80

100

120

 

 

 

AREA PER FIXTURE IN SQUARE FEET

 

 

3

4

5

6

7

8

9

10

11

CENTER TO CENTER DISTANCE OF FIXTURES IN FEET

This quick Calculator chart determines the number and spacing of 1 lt.-42W PL-T units with Comfort Clear™ reflector for any level of illumination.

Spacing Ratio

Spacing Ratio = 1.1

REPORT PREPARED FOR: LIGHTOLIER

REPORT NO: LRL 499-9F2

 

 

CANDLEPOWER SUMMARY

REPORT NO: LRL 499-9E

 

 

 

 

 

 

REPORT PREPARED FOR: LIGHTOLIER

ANGLE

AVERAGE CP

LUMENS

REPORT BY: LIGHTING RESEARCH LABORATORY, INC.

 

 

 

DESCRIP: 7.5” DIA. x 11 HT RECESSED DOWNLIGHT WITH COMFORT CLEAR™

REPORT BY: LIGHTING RESEARCH

 

 

 

180

 

0

 

 

REFLECTOR. LAMPS: 1PLT 42W

LUMENS=3200

 

 

 

 

LABORATORY, INC.

 

 

 

 

 

 

 

 

 

 

 

 

 

175

 

0

 

0

 

 

 

 

 

CANDLEPOWER SUMMARY

DESCRIP: 7.5” DIA. RECESSED DOWNLIGHT

165

 

0

 

0

 

 

 

 

85°

WITH COMFORT CLEAR™ REFLECTOR

 

155

 

0

 

0

 

 

 

 

 

 

 

 

LAMPS: 1PL-T 32W

LUMENS=2400

 

 

145

 

0

 

0

200

 

 

 

ANGLE

AVERAGE CP

LUMENS

 

 

 

 

 

 

135

 

0

 

0

 

 

 

 

75°

180

0

 

 

 

 

 

 

 

 

125

 

0

 

0

 

 

 

 

175

0

 

0

 

 

 

 

 

 

115

 

0

 

0

400

 

 

 

 

165

0

 

0

 

 

 

 

85°

 

105

 

0

 

0

 

 

 

 

65°

155

0

 

0

200

 

 

 

 

 

95

 

0

 

0

600

 

 

 

145

0

 

0

 

 

 

75°

 

85

 

1

 

1

 

 

 

 

135

0

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

 

2

 

2

 

 

 

 

 

125

0

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400

 

 

 

 

 

65

 

3

 

3

800

 

 

 

55°

115

0

 

0

 

 

 

65°

 

55

 

11

 

10

 

 

 

105

0

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

 

226

 

175

 

 

 

 

 

95

0

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

600

 

 

 

 

 

35

 

678

 

426

1000

 

 

 

 

85

2

 

2

 

 

 

 

 

25

 

933

 

432

 

 

 

 

 

75

4

 

4

 

 

 

 

55°

 

15

 

1117

 

317

1200

 

 

 

45°

65

5

 

5

800

 

 

 

 

 

5

 

1179

 

113

 

 

 

55

16

 

14

 

 

 

 

 

0

 

1126

 

 

 

 

 

 

 

45

334

 

258

 

 

 

 

 

ZONAL LUMENS AND PERCENTAGES

1400

 

 

 

 

35

797

 

501

 

 

 

 

45°

 

 

 

 

25

1178

 

545

1000

 

 

 

ZONE

LUMENS

% LAMP

%LUMINAIRE

 

 

 

 

 

15

1504

 

426

 

 

 

 

 

1600

 

 

 

 

5

1585

 

151

 

 

 

 

 

0-30

 

861

35.9

 

58.3

5°

15°

25°

35°

0

1518

 

 

1200

 

 

 

 

0-40

 

1287

53.6

 

87.1

0°

 

 

 

 

 

 

0-60

 

1472

61.3

 

99.6

 

 

 

 

ZONAL LUMENS AND PERCENTAGES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-90

 

1478

61.6

 

100.0

**Efficiency=59.6%**

 

0°

5°

15 °

25°

35°

40-90

 

191

8.0

 

12.9

 

ZONE

LUMENS

% LAMP

%LUMINAIRE

60-90

 

6

0.3

 

0.4

 

 

 

 

 

 

 

 

 

90-120

0

0.0

 

0.0

May 14, 1999

 

 

0-30

1123

35.1

 

58.9

**Efficiency=61.6%**

 

90-150

0

0.0

 

0.0

 

 

0-40

1623

50.7

 

85.1

 

90-180

0

0.0

 

0.0

 

 

 

 

0-60

1896

59.3

 

99.4

 

 

 

 

 

0-180

 

1478

61.6

 

100.00

 

 

 

 

0-90

1908

59.6

 

100.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40-90

284

8.9

 

14.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60-90

12

0.4

 

0.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90-120

0

0.0

 

0.0

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE

 

 

 

 

90-150

0

0.0

 

0.0

 

 

 

 

90-180

0

0.0

 

0.0

 

 

 

GREATEST LUMINOUS OPENING OF LUMINAIRE.

 

 

 

 

 

 

0-180

1908

59.6

 

100.00

Coefficients Of Utilization

 

 

 

 

EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

 

 

 

 

 

 

80

 

 

70

 

 

 

50

 

 

 

30

 

 

10

 

0

 

 

 

 

 

 

WALL REFLECTANCE

 

 

 

 

 

 

 

 

 

 

50

30

10

50

30

10

 

50

30

10

 

50

30

10

50

30

10

0

 

 

 

 

RATIO

1

.69

.67 .66

.67

.66

.65

 

.65

.64

.63

 

.63

.62

.61

.61

.60

.59

.58

2

.65

.63

.61

.64

.62

.60

 

.62

.60

.50

 

.60

.59

.58

.58

.57

.56

.56

 

3

.61

.59

.57

.61

.58

.56

 

.59

.57

.55

 

.58

.56

.55

.56

.55

.54

.53

CAVITY

4

.58

.55

.53

.57

.54

.52

 

.56

.54

.52

 

.55

.53

.51

.54

.52

.50

.50

6

.52

.48

.40

.51

.48

.40

 

.50

.48

.40

 

.50

.47

.45

.49

.47

.45

.44

 

5

.55

.51

.49

.54

.51

.49

 

.53

.50

.49

 

.52

.50

.48

.51

.49

.48

.47

ROOM

7

.49

.45

.43

.46

.45

.43

 

.48

.45

.43

 

.47

.44

.43

.46

.44

.42

.42

8

.46

.42

.40

.40

.42

.40

 

.45

.42

.40

 

.44

.42

.40

.44

.41

.40

.39

 

9

.43

.40 .37

.43

.39

.37

 

.42

.39

.37

 

.42

.39

.37

.41

.39

.37

.36

 

10

.38

.35 .32

.38

.35

.32

 

.38

.35

.32

 

.37

.34

.32

.37

.34

.32

.31

20% FLOOR CAVITY REFLECTANCE

Coefficients of Utilization

EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

 

 

 

80

 

 

70

 

 

50

 

 

30

 

 

 

10

 

 

 

 

 

 

 

 

WALL REFLECTANCE

 

 

 

 

 

 

 

 

 

50

30 10

 

 

 

 

 

 

 

 

 

 

 

50

30 10

0

 

 

50

30

10

50

30

10

50

30

10

 

1

.66

.65 .64

.65 .64 .63

.63 .62 .61

.60 .60

.59

 

.58

.58 .57

.56

RATIO

2

.62

.60 .58

.61 .59 .57

.59 .58 .56

.57 .56

.55

 

.56

.55 .54

.53

3

.58

.55 .53

.57 .55 .53

.56 .54 .52

.54 .53

.51

 

.53

.52 .50

.50

CAVITY

4

.55

.52 .49

.54 .51 .49

.53 .50 .48

.52 .50

.48

 

.51

.49 .47

.46

5

.51

.48 .46

.51 .48 .45

.50 .47 .45

.49 .46

.45

 

.48

.46 .44

.43

 

 

 

6

.48

.45 .42

.48 .45 .50

.47 .44 .42

.46 .44

.42

 

.45

.43 .41

.41

ROOM

7

.45

.42 .39

.45 .41 .39

.44 .41 .39

.43 .41

.39

 

.43

.40

.38

.38

8

.42

.39 .36

.42 .38 .36

.41 .38 .36

.40 .38

.36

 

.40

.37

.36

.35

 

 

 

9

.39

.36 .33

.39 .35 .33

.38 .35 .33

.38 .35

.33

 

.37

.35

.33

.32

 

10

.37

.33 .31

.36 .33 .31

.36 .33 .31

.35 .32

.30

 

.35

.32

.30

.30

Job Information

 

Type:

 

 

 

Lightolier a Genlyte Thomas Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902

Page 2
Image 2
Lightolier CS7142 Page 2 of, Quick Calculator, Spacing Ratio =, Coefficients Of Utilization, Job Information, Type