Lightolier DPB2S9LS26U Photometry, Options & Accessories, Specifications, Job Information, Type

Models: DPB2S9LS22U DPB2S9LS26U

1 2
Download 2 pages 30.58 Kb
Page 2
Image 2
PHOTOMETRY
Section 2A/Folio G50-84 REV. B

DEEPCELL SURFACE DPB2S9LS26U OR 22U

Page 2 of 2 2' x 2' SURFACE FLUORESCENT, 3" TYPE, 9 CELL PARABOLIC LOUVER, 2 LAMP T8 OR T12

PHOTOMETRY

G01021

DPB2S9LS26U120SO

MODEL NO. DPB2S9LS26U120SO coefficients of utilization — zonal cavity method

 

RF

 

20

 

 

20

 

 

20

 

 

RC

 

80

 

 

50

 

 

30

 

 

RW

70

50

30

50

30

10

50

30

10

ratio

1

66

64

62

60

58

57

58

56

55

3

56

50

46

48

44

41

46

43

41

 

2

61

57

53

53

51

48

52

49

47

cavity

4

51

45

40

43

39

36

41

38

35

5

47

40

35

38

34

31

37

34

31

room

6

44

36

31

35

31

27

34

30

27

8

38

30

25

29

25

22

28

24

22

 

7

41

33

28

32

27

24

31

27

24

 

9

35

28

23

27

23

20

26

22

20

 

10

33

26

21

25

21

18

24

20

18

visual comfort probability

room size

 

 

 

 

ceiling height

 

 

 

 

ceiling height

 

W

L

 

8.5

10.0

13.0

16.0

 

 

8.5

10.0

13.0

16.0

20

20

 

 

69

65

64

72

 

 

63

59

57

65

20

30

 

 

71

67

64

64

 

 

66

61

56

55

20

40

 

 

73

69

67

65

 

 

68

64

59

55

20

60

 

 

74

71

69

67

 

 

70

66

62

58

30

20

 

 

74

69

64

70

 

 

69

64

59

65

30

30

 

 

75

70

64

62

 

 

71

66

58

55

30

40

 

 

76

72

67

63

 

 

72

68

61

56

30

60

 

lengthwise

77

73

68

65

 

crosswise

74

69

63

58

40

40

 

78

75

69

63

 

75

71

64

58

30

80

 

 

78

74

70

67

 

 

75

71

65

60

40

20

 

 

77

73

68

69

 

 

72

69

63

66

40

30

 

 

78

74

67

63

 

 

73

70

62

57

40

60

 

luminaries

79

75

70

65

 

luminaries

76

72

66

60

40

80

 

80

76

72

67

 

77

74

68

62

40

100

 

 

80

77

73

68

 

 

77

75

69

64

60

30

 

 

79

75

70

65

 

 

76

72

65

60

60

40

 

 

80

76

71

65

 

 

77

73

67

60

60

60

 

 

80

77

72

67

 

 

77

74

68

62

 

 

60

80

 

 

80

78

73

68

 

 

78

75

70

64

60

100

 

 

81

78

74

69

 

 

79

76

71

65

100

40

 

 

81

78

74

70

 

 

78

75

70

64

100

60

 

 

81

79

74

70

 

 

79

76

71

65

100

80

 

 

82

79

75

71

 

 

79

77

72

67

100

100

 

 

82

80

76

72

 

 

80

77

73

68

ORDERING INFORMATION Explanation of Catalog Number. Example: DPB2S9LS26U120SOGLR

DP

 

B

 

2

 

S

 

 

 

 

 

S

2

 

 

 

 

 

 

 

DEEPCELL

 

FIXTURE

 

 

PARABOLIC:

 

WIDTH

 

 

Pre-anodized

 

 

 

 

 

Aluminum

 

 

 

 

 

Louver

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BODY STYLE:

 

 

 

CEILING

 

 

Surface Box

 

 

 

TYPE:

 

 

 

 

 

 

S=Surface

 

 

 

 

 

 

 

*Consult factory for availability of louver finishes.

NUMBER OF

BALLAST

CELLS

COVER

9 or 12

 

LOUVER FINISH*: L=Low-iridescencesemi-specular

(standard) P=Low-iridescence specular W=White Paint

LAMP

 

VOLTAGE:

 

OPTIONS:

QUANTITY:

 

120 or 277

 

Add appropriate suffix

(By Others)

 

 

 

to catalog no., ie: (GLR)

2=2 Lamp

 

BALLAST TYPE:

 

 

 

 

 

 

1-2 Lamp Mag. T12

LE

 

 

 

 

 

<20THD <10THD

LAMP/

1-2 Lamp Elec. T8

SO*

HI*

FIXTURE LENGTH:

LOL Dimming T8

PS

2U=T8, 1-5/8" U Lamp

*Instant Start Standard

 

6U=6" U Lamp T8 or

 

T12

Other dimming options. Consult factory.

(Nominal 24")

 

 

 

 

OPTIONS & ACCESSORIES

STEM AND CANOPY SETS: Suspends fixture 6", 12", 18" or 24" from surface.

(Four per fixture is required.) Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24").

FUSING: Internal fast-blow fusing.

SUFFIX: GLR.

Internal slow-blow fusing.

SUFFIX: GMF.

RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture is standard. SUFFIX: RF.

ELECTRICAL/WIRING OPTIONS Consult factory.

SPECIFICATIONS

PERFORMANCE: In an installation of 2U lamp 31W luminaires in a room cavi- ty ratio of 1, with a reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .64. To prevent glare the VCP shall be not less than 77 either lengthwise or cross wise (at 100fc level) and the average brightness at 65° shall not exceed 2319 footlamberts. To control veiling reflections, luminaire output in the 30°-90° zone shall be not less than 68.4%.

SPECIFICATIONS (continued)

MATERIALS: Chassis parts are die-formed 20 gauge cold rolled steel, stud- welded for rigidity with all seams finished smooth.

LOUVER: pre-anodized aluminum (Coilzak® or equal).

STANDARD FINISH: Louver—low iridescence, semi-specularpre-anodized vertical grain reflector sheet. Cavity—white baked acrylic enamel minimum 86% reflectance. Phosphate undercoating. Chassis exterior—white baked acrylic enamel.

ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS: I.B.E.W./UL and C-UL.

Job Information

 

Type:

 

 

 

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

Page 2
Image 2
Lightolier DPB2S9LS26U Photometry, Options & Accessories, Specifications, SPECIFICATIONS continued, Job Information, Type