Lightolier specifications Page 3 of, Lighting Systems EC1-13, Job Information, Type

Models: EC1-13

1 3
Download 3 pages 42.54 Kb
Page 3
Image 3
Page 3 of 3

Lighting Systems EC1-13

Page 3 of 3

 

 

Energos Control System 3-Light T5 per 4' (121.92cm) (Nominal) Lens

 

Ballast Ordering Information

 

 

Lamp Ordering Information

 

Design

Lamp Type

Ballast Factor

Start Type

THD %

Design

Lamp Type

Wattage

Rated Output

Color (K)

(Lumens)

 

 

 

 

 

 

 

 

 

F

T5

1.00

Program

<10

M

T5

28

2600*

3000

G

T5HO

1.00

Program

<10

N

T5

28

2600*

3500

I

Dim T5

1.00 / .01

Program

<10

O

T5

28

2600*

4100

J

Dim T5HO

1.00 / .03

Program

<10

P

T5

54

4450*

3000

 

 

 

 

 

Q

T5

54

4450*

3500

 

 

 

 

 

R

T5

54

4450*

4100

*25°C Rating

 

 

 

 

 

 

 

 

Lamp and Ballast System Data

 

 

 

 

 

 

 

 

 

 

Lamp Type

 

Ballast

 

Ballast

 

Lamp Rated

 

Lamp

 

Lamp

 

IES Output

 

System

 

System

 

System

 

Start

 

 

 

 

 

 

 

 

 

 

 

 

 

Design

 

 

 

 

Rated

 

Color

 

 

Input

 

Efficacy

 

Lamp Life

 

 

(T8 or T5)

 

Factor (BF)

 

THD (%)

 

Wattage

 

 

 

(lumens)

 

 

 

 

Type

 

 

 

 

 

 

Output

 

(Kelvin)

 

 

Watts

 

(lum/watt)

 

(Hours)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FM

T5

 

1

 

<10

 

28

 

2600

 

3000

 

2600

 

31.0

 

83.87

 

20000

 

Program

 

FN

T5

 

1

 

<10

 

28

 

2600

 

3500

 

2600

 

31.0

 

83.87

 

20000

 

Program

 

FO

T5

 

1

 

<10

 

28

 

2600

 

4100

 

2600

 

31.0

 

83.87

 

20000

 

Program

 

GP

HO

 

1

 

<10

 

54

 

4450

 

3000

 

4450

 

58.5

 

76.07

 

20000

 

Program

 

GQ

HO

 

1

 

<10

 

54

 

4450

 

3500

 

4450

 

58.5

 

76.07

 

20000

 

Program

 

GR

HO

 

1

 

<10

 

54

 

4450

 

4100

 

4450

 

58.5

 

76.07

 

20000

 

Program

 

IM

T5 DIM

 

1.0 / .01

 

<10

 

28

 

2600

 

3000

 

2600 / 26

 

33.5 / 8

 

77.60

 

NA

 

Program

 

IN

T5 DIM

 

1.0 / .01

 

<10

 

28

 

2600

 

3500

 

2600 / 26

 

33.5 / 8

 

77.60

 

NA

 

Program

 

IO

T5 DIM

 

1.0 / .01

 

<10

 

28

 

2600

 

4100

 

2600 / 26

 

33.5 / 8

 

77.60

 

NA

 

Program

 

JP

T5HO DIM

 

1.0 / .03

 

<10

 

54

 

4450

 

3000

 

4450 / 134

 

63 / 12.5

 

70.60

 

NA

 

Program

 

JQ

T5HO DIM

 

1.0 / .03

 

<10

 

54

 

4450

 

3500

 

4450 / 134

 

63 / 12.5

 

70.60

 

NA

 

Program

 

JR

T5HO DIM

 

1.0 / .03

 

<10

 

54

 

4450

 

4100

 

4450 / 134

 

63 / 12.5

 

70.60

 

NA

 

Program

*25°C Rating

 

 

 

 

 

 

 

 

 

 

Data is based on Osram Sylvania specifications.

 

 

 

 

All data is per 1 lamp on a two lamp system at 277 VAC.

 

 

 

 

 

When ordering no lamps provided by Lightolier, use lamp code “Z”.

 

Do not alter lumen values or ballast factor light losses when completing calculations using Energos IES files. Files have already been adjusted. The lumen value for the lamp (within a Lighting Design program) will be the IES Ouput value shown on this table.

Job Information

Type:

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 Philips Group • C0808

Page 3
Image 3
Lightolier specifications Page 3 of, Lighting Systems EC1-13, Job Information, Type, Lamp Ordering Information