Lighting Systems EC1-13
Page 3 of 3 |
|
| Energos Control System | |||||||
| Ballast Ordering Information |
|
| Lamp Ordering Information |
| |||||
Design | Lamp Type | Ballast Factor | Start Type | THD % | Design | Lamp Type | Wattage | Rated Output | Color (K) | |
(Lumens) | ||||||||||
|
|
|
|
|
|
|
|
| ||
F | T5 | 1.00 | Program | <10 | M | T5 | 28 | 2600* | 3000 | |
G | T5HO | 1.00 | Program | <10 | N | T5 | 28 | 2600* | 3500 | |
I | Dim T5 | 1.00 / .01 | Program | <10 | O | T5 | 28 | 2600* | 4100 | |
J | Dim T5HO | 1.00 / .03 | Program | <10 | P | T5 | 54 | 4450* | 3000 | |
|
|
|
|
| Q | T5 | 54 | 4450* | 3500 | |
|
|
|
|
| R | T5 | 54 | 4450* | 4100 |
*25°C Rating
|
|
|
|
|
|
|
| Lamp and Ballast System Data |
|
|
|
|
|
|
|
| ||||||
|
| Lamp Type |
| Ballast |
| Ballast |
| Lamp Rated |
| Lamp |
| Lamp |
| IES Output |
| System |
| System |
| System |
| Start |
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
| Design |
|
|
|
| Rated |
| Color |
|
| Input |
| Efficacy |
| Lamp Life |
| ||||||
| (T8 or T5) |
| Factor (BF) |
| THD (%) |
| Wattage |
|
|
| (lumens) |
|
|
|
| Type | ||||||
|
|
|
|
|
| Output |
| (Kelvin) |
|
| Watts |
| (lum/watt) |
| (Hours) |
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
| FM | T5 |
| 1 |
| <10 |
| 28 |
| 2600 |
| 3000 |
| 2600 |
| 31.0 |
| 83.87 |
| 20000 |
| Program |
| FN | T5 |
| 1 |
| <10 |
| 28 |
| 2600 |
| 3500 |
| 2600 |
| 31.0 |
| 83.87 |
| 20000 |
| Program |
| FO | T5 |
| 1 |
| <10 |
| 28 |
| 2600 |
| 4100 |
| 2600 |
| 31.0 |
| 83.87 |
| 20000 |
| Program |
| GP | HO |
| 1 |
| <10 |
| 54 |
| 4450 |
| 3000 |
| 4450 |
| 58.5 |
| 76.07 |
| 20000 |
| Program |
| GQ | HO |
| 1 |
| <10 |
| 54 |
| 4450 |
| 3500 |
| 4450 |
| 58.5 |
| 76.07 |
| 20000 |
| Program |
| GR | HO |
| 1 |
| <10 |
| 54 |
| 4450 |
| 4100 |
| 4450 |
| 58.5 |
| 76.07 |
| 20000 |
| Program |
| IM | T5 DIM |
| 1.0 / .01 |
| <10 |
| 28 |
| 2600 |
| 3000 |
| 2600 / 26 |
| 33.5 / 8 |
| 77.60 |
| NA |
| Program |
| IN | T5 DIM |
| 1.0 / .01 |
| <10 |
| 28 |
| 2600 |
| 3500 |
| 2600 / 26 |
| 33.5 / 8 |
| 77.60 |
| NA |
| Program |
| IO | T5 DIM |
| 1.0 / .01 |
| <10 |
| 28 |
| 2600 |
| 4100 |
| 2600 / 26 |
| 33.5 / 8 |
| 77.60 |
| NA |
| Program |
| JP | T5HO DIM |
| 1.0 / .03 |
| <10 |
| 54 |
| 4450 |
| 3000 |
| 4450 / 134 |
| 63 / 12.5 |
| 70.60 |
| NA |
| Program |
| JQ | T5HO DIM |
| 1.0 / .03 |
| <10 |
| 54 |
| 4450 |
| 3500 |
| 4450 / 134 |
| 63 / 12.5 |
| 70.60 |
| NA |
| Program |
| JR | T5HO DIM |
| 1.0 / .03 |
| <10 |
| 54 |
| 4450 |
| 4100 |
| 4450 / 134 |
| 63 / 12.5 |
| 70.60 |
| NA |
| Program |
*25°C Rating |
|
|
|
|
|
|
|
|
|
| Data is based on Osram Sylvania specifications. |
|
|
|
| |||||||
All data is per 1 lamp on a two lamp system at 277 VAC. |
|
|
|
|
| When ordering no lamps provided by Lightolier, use lamp code “Z”. |
|
Do not alter lumen values or ballast factor light losses when completing calculations using Energos IES files. Files have already been adjusted. The lumen value for the lamp (within a Lighting Design program) will be the IES Ouput value shown on this table.
Job Information | Type: |
631 Airport Road, Fall River, MA 02720 • (508)