Lighting Systems EC1-13
Page 2 of 3
Control Ordering Information
Energos Control System
Family | Series | Lamping & |
|
| Distribution |
EC |
| 1 |
|
| 3 |
|
3 = 3 lamp
Ballast
See Chart on Page 3
Lamp
See Chart on Page 3
Shielding
L
L = Duplex
Lens
| Length |
|
| Voltage |
| Finish | Options | ||||||
|
|
|
|
|
|
|
|
|
|
|
| (Blank) | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 4 = 4' (121.92cm) | 6 = 120 | Vac Master |
| A = Aluminum |
| 4 = 4 through wires | ||||||
| 8 = 8' (243.84cm) | 7 | = 277 | Vac Master |
| W=White |
| 5 = 5 through wires | |||||
|
|
| 8 | = 120 | Vac Slave |
|
|
|
| 6 = 6 through wires | |||
|
|
| 9 | = 277 | Vac Slave |
|
|
|
| D = Dual Switch | |||
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
| T = Tandem Switch | |
|
|
|
|
|
|
|
|
|
|
|
| E = Emergency |
Ordering Instructions
End Cap ECS Systems
1.Order Master 4' (121.92cm) or 8' (243.84cm) ECS Module.
2.Order Power Feed End Set.
Continuous Row Mounted ECS Systems:
1.Determine run length
2.Order a minimum of one master per run. Please see Application Guide for master requirements on runs that exceed 16' (487.68cm).
3.Order the required remaining Master and Slave modules to complete the run.
4.Order Power Feed End Set.
5.Order one CABLE ASSEMBLY per MODULE minus one per run.
6.Order additional Single Cable & Cord Sets for every Master Module in run.
ECS Sensor Sample Runs | ECS End Sets | |||
|
|
|
|
|
|
|
|
|
|
4' Run: 4' (121.92cm) Master Module with Single Sensor End Set.
|
|
|
| Single Sensor | Dual Sensor | Single Cable & |
8' Run: 8' (243.84cm) Master Module and standard Energos End Set. | End Set EC1SE36W | End Set EC1DE36W | Power Cord EGCC36 |
8' Run: 8' (243.84cm) Master Module and Dual Sensor End Set. |
|
| |||||
|
|
|
|
|
| Single Sensor SRL | Dual Sensor SRL |
|
|
|
|
|
| ||
12' Run:8' (243.84cm) Master Module, 4' (121.92cm) Slave Module, Dual | End Set EC1SR36W | End Set EC1DR36W | |||||
Sensor End Set, and Intermediate Cable Assembly. |
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
16' Run:8' (243.84cm) Master Module, 8' (243.84cm) Slave Module, standard Energos End Set, and Intermediate Cable Assembly.
16' Run:8' (243.84cm) Master Module, 8' (243.84cm) Slave Module, Single Sensor End Set, and Intermediate Cable Assembly.
16' Run:8' (243.84cm) Master Module, 8' (243.84cm) Slave Module, Single Sensor End Set, and Intermediate Cable Assembly.
Notes:
1.See page 1 of Specification Sheet or consult Application Guide for the definition of Serial Row Linking (SRL).
2.Consult the matching EG specification sheet for Luminaire related specifications (i.e. Housing materials, shielding, mounting dimensions, and photometry).
Standard End | SRL Standard |
Set EG1EC36W | End Set EC1ER36W |
Job Information | Type: |