AMPLIFIER PROTECTION | Full Short Circuit, Open Circuit, |
| ||
| RF Protection. Stable into reactive or mismatched loads. |
| ||
SPEAKER PROTECTION | DC Load Fault Protection |
|
| |
| 3 Second |
|
| |
COMPLEMENTARY OUTPUT DEVICES | 4 | 8 | 16 | 32 |
POWER SUPPLY | Single Transformer with Independent Isolated Secondary Windings, Fault | |||
| Fuses, Rectifiers, and Filter Capacitors |
|
| |
DIMENSIONS |
|
|
|
|
Faceplate Width | Standard 19" Rack Mounting |
|
| |
Faceplate Height | 1.75" | 5.25" | 5.25" | 7.0" |
Chassis Depth | 8.7" | 9.5" | 9.5" | 11.75" |
WEIGHT |
|
|
|
|
Shipping, Lbs | 15 | 28 | 37 | 57 |
Net, Lbs | 12 | 24 | 34 | 55 |
II: BASIC INSTRUCTIONS
2.1 UNPACKING AND INSPECTION
All QSC Series One amplifiers are fully tested and inspected before they leave the factory. Despite the protective carton and rugged amplifier design, it is possible for shipping abuse to damage the amplifier. Check for obvious carton damage while unpacking the unit. After removing the amp from the box, rotate it in all directions to check for loose parts inside.
Please save the carton for return shipment, if required. QSC does not warranty against damage caused by sending amplifiers back in the wrong carton.
If shipping damage is evident, notify the transportation company immediately. Only the consignee can file a claim with the carrier for shipping damage. QSC will cooperate fully in such an event. Be sure to save the carton for the shipper to inspect.
2.2 IMPORTANT PRECAUTIONS
2.21The power must be OFF when making any connections. If you connect plugs with the power on, especially in dry environments, static sparks or bad cables can cause pops or hums which can damage speakers.
2.22When first powering up the amp, have the amplifier Gain controls all the way off, in case of defective cables or hookups. Turn the Gain controls up gradually until normal operation is verified.
2.23Check the AC voltage printed on the serial number label to ensure your amplifier is properly configured for the AC voltage supplied in your area before connecting the AC plug.
CONNECTION TO A VOLTAGE SOURCE OTHER THAN THE ONE SPECIFIED WILL IMMEDIATELY DAMAGE THE AMP, AND VOIDS THE WARRANTY.
2.24Never connect the speaker terminals (red binding posts) for two channels together on any power amplifier. The two channels will fight each other and possibly fail. Do not connect the speaker ground terminals (black binding posts) to chassis or signal grounds, as the resultant ground loop could cause ultrasonic oscillations. In other words, keep all speaker wiring separate for each channel, and separate from input wiring.
2.25Do not remove the amplifier cover, as there are dangerous voltages inside. Do not expose to rain or moisture. Refer all servicing to qualified personnel. The warranty will be void if the amp is tampered with by
2.26The QSC Warranty does not cover tampering by unqualified personnel, or repairs made at