Page of 2

FC14U/FCA1

BrisaLinear Curve Surface Mount  FC14U

Wall/Ceiling Mounted T5 Fluorescent ADA Compliant

50

100

150

DECORATIVE LUMINAIRE CAT. # FC14U/FCA1 14W PHILIPS T-5

LAMPS. LUMEN RATING = 1200 LMS. BALLAST/ UNIVERSAL #B228PUNV-C

 

 

 

Candlepower Summary

 

90°

Angle

Along

22.5.

45

67.5

Across.

LumensOutput

0

182

182

182

182

182

 

 

5

182

182

182

182

182

17

 

15

176

176

177

177

177

50

 

25

164

165

166

166

166

77

 

35

147

148

149

150

150

93

 

45

125

126

127

129

129

98

 

55

98

100

102

104

105

91

60°

65

69

70

74

78

80

74

 

75

36

39

47

54

57

50

 

85

8

15

26

34

38

30

 

90

2

12

26

37

42

 

 

95

5

13

36

51

58

33

 

105

21

14

24

39

47

30

 

27

22

28

31

34

28

 

 

125

27

33

33

37

39

30

 

135

26

33

37

40

42

28

 

145

25

28

41

43

43

23

 

155

25

25

33

41

42

15

 

165

21

21

24

31

35

7

Coefficients of Utilization

Ceiling

 

80%

 

 

70%

 

 

50%

 

 

30%

 

 

10%

 

Wall

 

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

RCR

 

 

 

Zonal Cavity Method - Effective Floor Reflectance = 20%

 

 

 

 

 

 

 

 

 

 

 

0

.73 .73 .73 .73 .70

.70 .70 .70

.63

.63 .63 .57

.57 .57 .51

.51 .51 .48

 

1

.67

.63 .61 .58

.63

.60 .58 .56

.55 .53 .51 .49

.48 .47 .45

.43 .42 .40

 

2

.60

.55 .51

.47

.57

.53 .49 .45

.48

.45

.42

.43

.41

.39

.39

.37 .35 .33

Ratio

3

.55

.49 .44

.40

.52

.46 .42

.38

.42

.38

.35

.38

.35

.33

.35

.32

.30 .28

4

.50

.43 .38 .33

.48

.41 .36 .32

.37

.33

.30

.34

.31

.28

.31

.28 .26 .24

 

Cavity

5

.46

.38 .32

.28

.43

.36 .31

.27

.33

.29

.26

.30

.26

.24

.27

.24

.22 .20

6

.42 .34 .28 .24 .40

.32 .27 .23

.30

.25

.22

.27

.23

.21

.25

.21

.19

.17

Room

7

.39

.30 .25

.21

.37

.29 .24 .20

.27

.22

.19

.24

.21

.18

.22

.19

.17

.15

8

.36

.27 .22

.18

.34

.26 .21

.18

.24

.20

.17

.22

.18

.15

.20

.17

.14

.13

 

9

.33

.25 .19

.16

.31

.24 .19

.15

.22

.17

.14

.20

.16

.13

.18

.15

.12

.11

10 .31 .22 .17 .14 .29 .21 .17 .13 .20 .15 .13 .18 .14 .12 .16 .13 .11 .10

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 20.0

200

 

175

25

23

20

15

13

2

30°

180

20

20

20

20

20

 

Zonal Lumens and Percentages

Zone

Lumens

% Lamp

%Luminaire

0-30

143

11.98

18.51

0-40

237

19.76

30.53

0-60

426

35.56

54.93

0-90

579

48.31

74.63

40-90

342

28.55

44.10

60-90

153

12.75

19.70

90-180

197

16.43

25.37

0-180

776

64.74

100.00

** Efficiency = 64.7% **

Certified Test Report no.3629FR Computed by LSI Program **TEST-LITE** SC = 1.3

Prepared For:

Lightolier

Fall River, MA

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE

TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

Job Information

Type:

 

 

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 Philips Group • C0408

Lightolier is a Philips group brand

Page 2
Image 2
Lightolier FC14U dimensions Coefficients of Utilization, Zonal Lumens and Percentages