This fixture is intended for installation in accordance with the National Electrical Code and local
regulations. To assure full compliance with local codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding. This fixture is intended for ceiling mounting and is suitable for damp locations.
Retain these Instructions for maintenance reference. -
INSTALLATION OF DOWNLIGHT
A. INSTALL WHITE TRIM RING
NOTE Omit this sactlon If reflector is
1.For overlappin trim installation (Fig. 1), slip WHITE TRIM RING over REFLEC#R, as shown in Fig. 2 and 3.
2.For flangeless trim installation (Fig. 4), WHITE TRIM RING is not required.
B.SNABIN
Align TABS on SOCKET CUP with openings in REFLECTORand push in SOCKET CUP until RETAINING SPRING snaps in (Fig. 5).
C.
1.Tilt REFLECTOR and insert SOCKET CUP into ceiling opening on side opposite JUNCTION BOX. Pivot REFLECTOR and push it up into ceiling (Fig. 6).
N~E To remove REFLECTOR, disengsge the SOCKET CUP by depressing the RETAINING SPRING (Fig. 5). Turn REFLECTOR
counterolockwlse while pulling downward. After starting, use both hands to ramov~ If desired. See Fig. 7.
D.LAMPING
lnserI lamp, tip first through hole in side of reflector opposite lamp SOCKETS. Bring lamp to horizontal position, line up pins, and push into socket (Fig.8). To relamp, carefully pull straight out of socket, tilt base downward, and remove lamp.
@
FIG. 1
WHITE
TRIM
,,$y RING
.. | ../“ |
|
REFLECTOR |
|
|
OR LENS TRIM |
|
|
FIG. 2 | FIG. 3 |
:: .:. Y.
,,. ..
@
—
INSTALLATION OF LENS WALL WASHER AND OPEN
WALL WASHER
NOTE. aafore Installing reflector, make sure the mountingframe IS Installed with JUNCTION BOX away from the wall to ba illuminated
(Fig. 10A or 10B).
FOR OPEN WALL WASHER
1.Remove two RETAINING SPRINGS that are near the JUNCTION BOX from the MOUNTING FRAME (Fig 9).
2.Insert two new RETAINING SPRINGS, that are provided with the reflector trim, into pocket of MOUNTING FRAME (Fig. 9A).
3.Then squeeze RETAINING SPRING into position with a plier (Fig. 9A).
RETAINING |
|
SPRING |
|
REMOVED 1 | m |
v
*
FK3. 4
FIG. 5
mTO REMOVE
““E=JuwREFLEcTOR