GO2 Retro
GO2 Retro features a flat white louver and a unique power tray that can be used to convert most installations of 2'X4' or 2'X2' parabolic or specification grade lens
troffers, that are at least 4 3/8" deep, to state of the art, energy saving GREEN FIXTURES. GO2 Retro is over 80% efficient with a broad light distribution that will illuminate both horizontal and vertical surfaces, creating a comfortable balanced brightness.
Retrofitting with GO2 Retro as opposed to installing new fixtures is ideal for those areas where you would like to have a minimum of down time such as retail spaces or schools.
P e r f o r m a n c e
42 GO2 Retro 2' x 4' |
| 60' x 56' x 9' Room |
|
| Reflectance 80/50/20 |
|
|
|
|
|
| |||||
Catalog Number |
| Ballast |
| Efficiency |
| Total Light |
| Average |
| Max/Min |
| Input Watts |
| Watts/ |
| Energy |
|
|
|
|
|
|
|
| |||||||||
| Factor |
|
| Loss Factor |
| Footcandles |
| Uniformity |
|
| Sq. Ft. |
| Savings | |||
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GOR2G232UNVC5* |
| 0.77 | 84.5% |
| 0.67 |
| 48.4 |
| 1.3 : 1 | 48 | 0.60 | 40% | ||||
Instant start ballast, |
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GOR2G232UNVC2 |
| 0.87 | 84.5% |
| 0.76 |
| 55.9 |
| 1.4 : 1 | 54 | 0.68 | 33% | ||||
Instant start ballast, |
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GOR2G232UNVCO |
| 1.18 | 84.5% |
| 1.03 |
| 74.0 |
| 1.3 : 1 | 72 | 0.90 | 10% | ||||
Instant start ballast, |
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*This layout of GO2 Retro will consume 10% to 40% less energy than the current LEED requirement of 1.0 watts per square foot depending on the ballast used. Footcandle readings are 2 1/2 ft off the floor 2 1/2 ft on center.
1058 GO2 Retro 2' x 4' |
| 376' x 280' x 16' Room | Reflectance 80/50/20 |
|
|
|
|
|
|
| |||||||
Catalog Number |
| Ballast |
| Efficiency |
| Total Light |
| Average |
| Max/Min |
| Input Watts |
| Watts/ |
| Energy | |
|
|
|
|
|
|
|
| ||||||||||
| Factor |
|
| Loss Factor |
| Footcandles |
| Uniformity |
|
| Sq. Ft. |
| Savings | ||||
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GOR2G232UNVC2 |
| 0.87 | 84.5% | 0.76 |
| 46.4 |
| 2.58 : 1 | 54 | 0.54 | 46% |
| |||||
Instant start ballast, |
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GOR2G232UNVCO |
| 1.18 | 84.5% | 1.03 |
| 52.7 |
| 1.5 : 1 | 72 | 0.72 | 28% |
| |||||
Instant start ballast, |
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*This layout of GO2 Retro will consume 28% to 46% less energy than the current LEED requirement of 1.0 watts per square foot depending on the ballast used. Footcandle readings are 2 1/2 ft off the floor 2 1/2 ft on center.
O r d e r i n g
Catalog Number | Fixture Size | Number of Lamps | Lamp Type | Ballast Type | Ballast Factor |
|
|
|
|
|
|
|
|
|
|
|
|
GOR2G217UNVHI | 2' X 2' | 2 | 17W T8 | Instant Start | 0.87 |
|
|
|
|
|
|
GOR2G214UNVPG | 2' X 2' | 2 | 14W T5 | Program Rapid Start | 0.87 |
|
|
|
|
|
|
GOR2G224UNVPG | 2' X 2' | 2 | 24W T5HO | Program Rapid Start | 1.1 |
|
|
|
|
|
|
GOR2G217UNVC2 | 2' X 4' | 2 | 32W T8 | Instant Start | 0.87 |
|
|
|
|
|
|
GOR2G232UNVHI | 2' X 4' | 2 | 32W T8 | Instant Start | 0.87 |
|
|
|
|
|
|
GOR2G232UNVC5 | 2' X 4' | 2 | 32W T8 | Instant Start | 0.77 |
|
|
|
|
|
|
GOR2G228UNVPG | 2' X 4' | 2 | 28W T5 | Program Rapid Start | 0.95 |
|
|
|
|
|
|
GOR2G254UNVPG | 2' X 4' | 2 | 54W T5HO | Program Rapid Start | 1.0 |
|
|
|
|
|
|
*Catalog number includes Advance Optanium high efficiency low watt ballast and Philips Alto Advantage 3100 lumen Lamps. GO2 Retro 2x2 is not available with an Emergency Pack option. Consult your Lightolier Sales Team.