| Guardsman Vandal Resistant GSW SERIES |
Page 1 of 2 | Ceiling or Wall Mounted Fluorescent |
| 6" Width, |
Photometry | Model No. GSW4232120SO |
G97001
GSW4232120SO
ADVANCE RIC2S32TP SOLID STATE
OCTRON BALLAST
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.
LER = FP - 62.9 |
| IW - 59.1 | BF - 0.88 |
|
|
|
|
|
| ||
Comparative yearly lighting energy cost per 1000 lumens = $4.06 |
|
|
| ||||||||
coefficients of utilization — zonal cavity method |
|
|
|
|
|
| |||||
| RF |
|
| 20 |
|
| 20 |
|
| 20 |
|
| RC |
|
| 80 |
|
| 50 |
|
| 30 |
|
| RW |
| 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
| 1 |
| 81 | 76 | 73 | 67 | 65 | 62 | 62 | 60 | 58 |
ratio | 2 |
| 73 | 66 | 61 | 58 | 54 | 51 | 54 | 51 | 48 |
3 |
| 66 | 58 | 51 | 51 | 46 | 42 | 47 | 43 | 40 | |
|
| ||||||||||
cavity | 4 |
| 61 | 51 | 44 | 46 | 40 | 36 | 42 | 38 | 34 |
5 |
| 56 | 46 | 39 | 41 | 35 | 31 | 38 | 33 | 29 | |
room | 6 |
| 51 | 41 | 34 | 37 | 31 | 27 | 34 | 29 | 26 |
7 |
| 48 | 37 | 30 | 33 | 28 | 24 | 31 | 26 | 23 | |
| 8 |
| 44 | 34 | 27 | 31 | 25 | 21 | 29 | 24 | 20 |
| 9 |
| 41 | 31 | 25 | 28 | 23 | 19 | 26 | 22 | 18 |
| 10 |
| 39 | 29 | 23 | 26 | 21 | 17 | 24 | 20 | 17 |
visual comfort probability
room size |
|
|
|
| ceiling height |
|
|
|
| ceiling height |
| ||
W | L |
|
| 8.5 | 10.0 | 13.0 | 16.0 |
|
| 8.5 | 10.0 | 13.0 | 16.0 |
20 | 20 |
|
| 40 | 47 | 58 | 69 |
|
| 30 | 39 | 53 | 66 |
20 | 30 |
|
| 35 | 40 | 46 | 56 |
|
| 20 | 27 | 35 | 48 |
20 | 40 |
|
| 33 | 36 | 41 | 47 |
|
| 15 | 20 | 26 | 35 |
20 | 60 |
|
| 32 | 35 | 38 | 42 |
|
| 11 | 15 | 19 | 25 |
30 | 20 |
|
| 38 | 45 | 55 | 66 |
|
| 32 | 40 | 51 | 64 |
30 | 30 |
|
| 32 | 37 | 43 | 52 |
|
| 22 | 27 | 35 | 46 |
30 | 40 |
|
| 30 | 33 | 38 | 43 |
|
| 16 | 20 | 26 | 33 |
30 | 60 |
|
| 29 | 32 | 34 | 39 |
|
| 12 | 15 | 19 | 25 |
30 | 80 |
| lengthwise | 29 | 31 | 33 | 37 |
| crosswise | 10 | 12 | 15 | 20 |
40 | 40 |
| 29 | 32 | 36 | 42 |
| 18 | 22 | 26 | 33 | ||
40 | 20 |
|
| 38 | 45 | 53 | 64 |
|
| 34 | 42 | 52 | 63 |
40 | 30 |
|
| 31 | 36 | 42 | 51 |
|
| 24 | 29 | 36 | 46 |
40 | 60 |
| luminaries | 27 | 30 | 32 | 37 |
| luminaries | 13 | 16 | 19 | 25 |
40 | 80 |
| 27 | 30 | 31 | 35 |
| 10 | 13 | 15 | 20 | ||
|
|
|
| ||||||||||
40 | 100 |
|
| 27 | 30 | 31 | 34 |
|
| 9 | 11 | 13 | 16 |
60 | 30 |
|
| 31 | 36 | 41 | 49 |
|
| 25 | 31 | 37 | 47 |
60 | 40 |
|
| 28 | 31 | 35 | 41 |
|
| 19 | 23 | 27 | 34 |
60 | 60 |
|
| 26 | 29 | 31 | 36 |
|
| 14 | 17 | 20 | 25 |
|
|
| |||||||||||
60 | 80 |
|
| 25 | 28 | 29 | 33 |
|
| 11 | 14 | 16 | 20 |
60 | 100 |
|
| 25 | 27 | 29 | 32 |
|
| 9 | 11 | 13 | 17 |
100 | 40 |
|
| 29 | 31 | 34 | 40 |
|
| 23 | 27 | 30 | 37 |
100 | 60 |
|
| 25 | 28 | 30 | 34 |
|
| 16 | 20 | 22 | 27 |
100 | 80 |
|
| 24 | 26 | 28 | 32 |
|
| 13 | 16 | 18 | 22 |
100 | 100 |
|
| 23 | 26 | 27 | 30 |
|
| 11 | 13 | 15 | 18 |
Ordering Information
Explanation of Catalog Number. Example: GSW4232120SOEM
GSW
GSW: | Fixture | Lamp Quantity: | Lamp: | Voltage: |
Guardsman | Length: | 1 or 2 Lamps | (By Others) | 120 or 277 |
Surface/Wall | 2 = 24" |
| 17 = T8 2' Length |
|
Vandal Resistant | 4 = 48" |
| 32 = T8 4' Length |
|
Fluorescent |
|
|
|
|
Ballast Type: |
| Options: | |
| <20THD <10THD | Add appropriate | |
SO* | HI* | suffix to catalog | |
0° Starting T8 | SD* | – | no, ie: (EM) |
LOL Dimming T8 | PS* | – |
|
*Instant Start Standard
Other dimming options, consult factory.
Options & Accessories
Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture
standard. Suffix: R. One per ballast. Suffix: B.
Emergency Power Pack: Factory installed emergency power pack includes charger and inverter concealed in fixture channel. Upon loss of AC power, oper- ates one lamp at reduced light. Suffix: EM.
Stem and Canopy Sets: Suspends fixture 6", 12", 18" or 24" from surface.
Catalog Number: ASC6 CSP | (6") |
ASC12 CSP | (12") |
ASC18 CSP | (18") |
ASC24 CSP | (24") |
Specifications
Materials: Chassis parts are
Specifications (continued)
Finish: Chassis
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc listed.
Job Inform ation |
| Type: |
|
|
|
Lightolier a Genlyte Thomas Company | www.lightolier.com |
Technical Information: (978)
631 Airport Road, Fall River, MA 02720 • (508)