Diagnostics & Troubleshooting

Send DS1 Payload Pattern

An external Bit Error Rate Tester (BERT) can be located anywhere on the network or at the customer premises as shown in the figure.

When testing is complete, the send ds1 <n> off command must be used to turn off the test pattern.

NOTE: The p2e patterns are intended only for Access Navigator loop tests and for tests between two Access Navigators. Other test equipment will not recognize these patterns.

NOTE: This command works with ESF and D4 (SF) framing.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Access Navigator

 

 

 

 

 

 

 

 

 

 

 

 

 

Payload

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Code

 

 

 

 

 

Framed

 

 

 

 

Pattern

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Generator

 

 

 

 

 

Pattern

 

 

 

Command

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time Slot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Line

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Framer

 

 

 

 

 

Interface

 

 

 

Interchange

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Far End

Bit Error Rate Test

Payload

Test

BERT

IN

DS1 OUT CSU DS0s

Figure 15-24. Send DS1 Payload Pattern

Syntax: send ds1 <n> payload <allonesallzerosf1in8p2e11p2e15p2e23qrss>

Field

Description

 

 

n

DS1 number, 1 to 32, or a range of numbers such as 2-8.

 

 

allones

Send framed all-ones pattern. This can be used as a “keep alive”

 

signal, idle code, and in measuring the T1 power level.

 

 

allzeros

Send framed all-zeros pattern. This can be used to test T1 circuits

 

for B8ZS clear channel capability and to find equipment

 

incorrectly set to AMI line code.

 

Note: When using an all-zeros pattern, a T1 test set (such as a

 

T-Berd 224 or Sunset T3) must be used to monitor for errors in

 

the all-zeros pattern from the Access Navigator or looped back

 

from a far-end network element.

 

 

f1in8

Send framed 1-in-8 pattern (also called a 1-and-7 pattern) in

 

which each payload byte contains the bit pattern 01000000.

 

(Minimal ones density test for T1 circuits with AMI coding.)

 

 

p2e11

Send 211–1 pattern with a maximum of 10 consecutive zeros and

 

11 consecutive ones. (Minimum stress testing.)

 

 

Access Navigator - Release 1.8

August 2003

15-45

Page 387
Image 387
Carrier Access user manual Access Navigator Payload Code