Carrier Access Access Navigator user manual Set System Clock Source

Models: Access Navigator

1 704
Download 704 pages 57.28 Kb
Page 205
Image 205

Provision DCS Service

Set System Clock Source

Set System Clock Source

NOTE: If Access Navigator provides GR-303 call support, the primary and secondary clock sources are usually set to “switch” DS1s in the GR-303 interface group.

1.Show current clock settings with the following command: show clock

This command will produce a message similar to the following:

Primary Master Transmit Clock Source: DS1 1

Secondary Master Transmit Clock Source: DS1 25

2.If clock settings are correct, skip remaining steps.

3.If primary clock setting is incorrect, set clock1 source with the following command: set clock1 <setting>

Example: set clock1 bits

There are three different settings, which are defined as follows:

Setting

Definition

bits

Select external or BITS source on Timing In connector

ds1 <n>

Select clock recovered from DS1 number n

internal

Select internal oscillator

4.If secondary clock setting is incorrect, set clock2 source with the following command: set clock2 <setting>

Example:

set clock2 ds1 5

Choose setting from list in previous step.