Provision Remote Adit 600 via FDL

Provision DS0 Crossconnects (if required)

NOTE: To change existing DS0 connections, you must first disconnect them before making new connections.

3.Disconnect existing DS0s with the following command: disconnect <n:ch>

Example: disconnect 10:16-24

4.Connect DS0s (see Figure 1) to make 2-way connections between DS0s, or fractional groups of DS0s, with the following command:

connect <n:ch> <n:ch>

Example: connect 10:16 18:21

Example: connect 16:17-24 21:5-12

(A)DS1 #10

(B)DS1 #12

(C)DS1 #15

(D)DS1 #16

DS0 #16

DS0 #3

DS0 #7

DS0 #17-24

Access Navigator

DS0 #10

DS1 #17

DS0 #21

DS1 #18

DS0 #4

DS0 #5-12

DS1 #21

Command Examples: (A) connect ds0 10:16 18:21

(B)connect ds0 12:3 17:10

(C)connect ds0 15:7 21:4

(D)connect ds0 16:17-24 21:5-12

Figure 12-3. Crossconnect Examples

12-16

August 2003

Access Navigator - Release 1.8

Page 294
Image 294
Carrier Access Access Navigator user manual Crossconnect Examples