Diagnostics & Troubleshooting

Send DS1 Payload Pattern with BER Test

Syntax: send ds1 <n> payload <allonesallzerosf1in8p2e11p2e15p2e23qrss> test

Field

Description

 

 

n

DS1 number, 1 to 32, or a range of numbers such as 2-8.

 

 

allones

Send framed all-ones pattern. This can be used as a “keep alive”

 

signal, idle code, and in measuring the T1 power level.

 

 

allzeros

Send framed all-zeros pattern. This can be used to test T1 circuits

 

for B8ZS clear channel capability and to find equipment

 

incorrectly set to AMI line code.

 

Note: When using an all-zeros pattern, a T1 test set (such as a

 

T-Berd 224 or Sunset T3) must be used to monitor for errors in

 

the all-zeros pattern from the Access Navigator or looped back

 

from a far-end network element.

 

 

f1in8

Send framed 1-in-8 pattern (also called a 1-and-7 pattern) in

 

which each payload byte contains the bit pattern 01000000.

 

(Minimal ones density test for T1 circuits with AMI coding.)

 

Note: You must wait 30 seconds after the prompt appears before

 

doing another test.

 

 

p2e11

Send 211–1 pattern with a maximum of 10 consecutive zeros and

 

11 consecutive ones. (Minimum stress testing.)

 

 

p2e15

Send 215–1 pattern with a maximum of 14 consecutive zeros and

 

15 consecutive ones. (Provides maximum number of consecutive

 

zeros permissible in framed, non-B8ZS testing.)

 

 

p2e23

Send 223–1 pattern with a maximum of 22 consecutive zeros and

 

23 consecutive ones. (Maximum stress testing.)

 

 

qrss

Send QRSS pattern (a modified 220–1) with a maximum of 14

 

consecutive zeros and 20 consecutive ones. (Common stress test

 

for T1 data applications.)

 

 

Example: send ds1 9 payload p2e15 test

For most patterns, the CLI will provide a progress message indicating the success (ok) or failure of the command followed by the test results, as in the following samples.

Message: Waiting for pattern sync........ok.

 

 

Testing line...

BE:0

CRC:0

BPV/LCV:0

08:15:47

FBE:0

08:15:48

FBE:0

BE:0

CRC:0

BPV/LCV:0

08:15:49

FBE:0

BE:0

CRC:0

BPV/LCV:0

08:15:50

FBE:0

BE:0

CRC:0

BPV/LCV:0

08:15:51

FBE:0

BE:0

CRC:0

BPV/LCV:0

08:15:52

FBE:0

BE:0

CRC:0

BPV/LCV:0

08:15:54

FBE:0

BE:0

CRC:0

BPV/LCV:0

08:15:55

FBE:0

BE:0

CRC:0

BPV/LCV:0

15-50

August 2003

Access Navigator - Release 1.8

Page 392
Image 392
Carrier Access Access Navigator user manual Field Description, Example send ds1 9 payload p2e15 test