Provision DCS Service

Provision “Groom” DS1 Circuits to Network

Provision “Groom” DS1 Circuits to Network

1.Show groom DS1 settings with the following command: show ds1 <n>

Example: show ds1 10

The show command will produce a message showing the DS1 settings. For example, the message for DS1 number 10 might look similar to the following:

Settings for DS1 10:

CA DS1# 10

 

 

Circuit ID:

 

 

Up/Down:

DOWN

 

 

 

Framing:

ESF

 

 

 

Line Coding:

B8ZS

 

 

 

Type:

DROP

 

 

 

Clock Source:

NORMAL

 

 

Line Build Out:

DSX-1 EQUALIZATION FOR 0-133 ft.

Loop Code Detection:

OFF

 

 

 

Loop Back:

OFF

 

 

 

Line Termination ID:

0 (for switch DS1s only)

 

FDL Type:

CAC

 

 

 

Send Code:

None

15 min.

1 hour

1 day

Performance Thresholds:

 

unavailable seconds:

 

--------

-------

------

 

0

0

0

severely errored seconds:

0

0

0

errored seconds:

 

0

0

0

sev. errored frame seconds:

0

0

0

degraded minutes:

 

0

0

0

linecode violations:

 

0

0

0

NOTE: In the above message loop back test function is turned off and the send code set to none during normal service. Line Termination IDs are used only for GR-303 switch DS1s.

2.If groom DS1 settings are correct, skip remaining steps.

3.Set DS1 type to “groom” with the following command: set ds1 <n> type groom

Example:

set ds1 10 type groom

4.Set groom DS1 frame type to D4 or ESF with the following command: set ds1 <n> framing <d4esf>

Example:

set ds1 10 framing esf

9-12

August 2003

Access Navigator - Release 1.8

Page 206
Image 206
Carrier Access Access Navigator user manual Provision Groom DS1 Circuits to Network, Cac