Provision Remote Adit 600 via FDL

Remote Adit 600 FDL Provisioning Quick Guide

Remote Adit 600 FDL Provisioning Quick Guide

CLI Commands

Descriptions

status equipment

Verify equipment configuration.

show ds1 <n>all>

Verify service status.

status ds1 <n>

 

status ds0 <n:ch>

 

set ds1 <n> down

Set unused circuits out of service

set ds0 <n:ch> down

(down). If the DS1 is not terminated,

set ds0 <n:ch> type <voicedata>

set the DS0 type of all channels to

 

 

data. If the DS1 is terminated, set the

 

 

DS0 type of any unused channels to

 

 

match the DS0 type (voice or data)

 

 

configured on the device at the other

 

 

end of the DS1.

 

 

set ds1 <n> type drop

DS1 type for remote Adit 600.

set ds1

<n> framing <d4esf>

DS1 framing. Use ESF for FDL.

set ds1

<n> linecode <amib8zs>

DS1 line code. Use B8ZS for FDL.

set ds1

<n> id <"id">

DS1 identifier.

set ds1

<n> clock <normalloop>

DS1 clock source.

set ds1

<n> fdl none

DS1 FDL type for remote Adit.

set ds1 <n> remote device mgmt cafdl

Set drop DS1 to remote Adit on to use

 

 

Carrier Access FDL protocol.

set ds1 <n> remote device mgmt ds1 <n>

Set all other drop DS1s to same

 

 

remote Adit to point to DS1 using

 

 

CAFDL.

 

 

set ds1 <n> lbo <setting>

DS1 line buildout.

set ds1 <n> loopdetect <onoff>

Usually off for drop DS1s.

show connect <n>

Verify DS0 crossconnections.

disconnect <n:ch>

Remove old DS0 connections (if any).

set ds0 <n:ch> type <voicedatagr303>

DS0 type.

set ds0 <n:ch> signal <lsgsem>

DS0 signaling (voice or GR-303 types

 

 

only).

connect <n:ch> <n:ch>

Add DS0 crossconnections.

12-4

August 2003

Access Navigator - Release 1.8

Page 282
Image 282