Provision Remote Access Bank II

Configure Remote RS-232 Interface (if used)

Configure Remote RS-232 Interface (if used)

NOTE: The RS-232 interface supports baud rates from 1,200 to 57,600 between two Access Bank II’s and uses a special format to transport asynchronous data over the synchronous DS0 channel.

1.Show current remote interface settings with the following command: show remote <nall>

Example: show remote 11

Example: show remote all

The show command will display the remote interface settings the each DS1 specified, or for all DS1s. For example, the message for showing DS1 number 11 would look similar to the following:

Settings for remote device Remote Device #11:

Remote

Config:

enabled

T1 Drop Port:

AMI

Line

Coding:

Framing:

D4

Line

Build Out:

DSX-1 0-133 ft. (or 0 db)

PRM:

 

AT&T

V.35 Port:

Always High

CTS:

 

Rx Timing:

Internal

Clock Inversion:

None

Data

Inversion:

Normal

Speed:

Nx64

DSU:

 

On

RS232 Port:

9,600

Baud

Rate:

Data

Bits:

8

Parity:

None

Stop

Bits:

1

2. If remote RS-232 interface settings are correct, skip remaining steps

11-22

August 2003

Access Navigator - Release 1.8

Page 270
Image 270
Carrier Access Access Navigator user manual Configure Remote RS-232 Interface if used