CLI Language Reference

CLI Command List

Example: send ds1 9 payload f1in8 test

For the 1-in-8 and all-zeros patterns, the CLI will provide a progress message indicating the success (ok) or failure of the command, followed by a pattern detection message for each second of the test.

Message: Waiting for pattern sync........ok.

Testing line...

08:18:23

Pattern Not Present

08:18:24

Pattern Present

08:18:25

Pattern Present

08:18:26

Pattern Present

08:18:27

Pattern Present

08:18:28

Pattern Present

08:18:29

Pattern Present

08:18:30

Pattern Present

08:18:31

Pattern Present

08:18:32

Pattern Present

Signaling done.

Description:

Item

Description

 

 

Time

Time is recorded in one-second intervals. Format is 24-hour

 

clock in hours:minutes:seconds with colons to separate the digits,

 

as in 08:30:45 and 15:22:10.

 

 

FBE

Number of Frame Bit Errors (4095 maximum) in one-second

 

interval

 

 

BE

Number of Bit Errors (4095 maximum) in one-second interval

 

 

CRC

Number of Cyclical Redundancy Check errors (1023 maximum)

 

in one-second interval

 

 

BPV/LCV

Number of Bi-Polar Violations and Line Code Violations

 

(16,383 maximum) in one-second interval

 

 

Totals

Total number of errors for 10-second test interval

 

 

Error Rates

Total error rates measured during the 10-second test interval,

 

expressed in scientific notation where "e" indicates a power of

 

10. For example, 1 error per 1.544 megabits is 6.520000e-07.

 

The maximum value is 2.700000e-03.

 

 

18-80

August 2003

Access Navigator - Release 1.8

Page 536
Image 536
Carrier Access Access Navigator user manual Example send ds1 9 payload f1in8 test