Update Controller Card Software

Verify Equipment Status

Verify Equipment Status

1.If you are not currently logged into the Access Navigator, start an RS-232 or Telnet management session.

2.Verify current Controller software version with the following command:

status equipment all

A message similar to the following will appear, showing the Controller cards installed and the software version.

Equipment

Status

Version

---------

------

-------

Controller A

Active

01.77 GR-303 Option

Controller B

Standby

01.77 GR-303 Option

DS1 Card 1

Installed

1

DS1 Card 2

Installed

1

DS1 Card 3

Installed

1

DS1 Card 4

Installed

1

DS1 Card 5

Installed

1

DS1 Card 6

Installed

1

DS1 Card 7

Card not installed

1

DS1 Card 8

Card not installed

1

 

 

 

Active

Standby

SW Build Number

------

-------

17701

17701

Boot

Code

Revision

01.09

01.07

FPGA

Code

Revision

1.06

1.06

Requirement: One Controller is in “Standby”.

WARNING! DO NOT CONTINUE THIS PROCEDURE IF THE CONTROLLER VERSION IS

01.70UP TO AND INCLUDING 01.80 OR IF THE BOOT CODE REVISION IS 01.07 OR

01.08.USE THE UPGRADE PROCEDURE IN PRODUCT TECHNICAL NOTE PTN-03-004,AVAILABLE BY CALLING CARRIER ACCESS CUSTOMER SUPPORT AT (800) 495-5455.

CAUTION! DO NOT CONTINUE THIS PROCEDURE IF ONE CONTROLLER IS NOT IN STANDBY. THIS INDICATES THE SYSTEM IS NOT PROTECTED BECAUSE THE SECOND CONTROLLER IS EITHER NOT OPERATIONAL (STATUS UNKNOWN) OR IS NOT INSTALLED.

IF THE CONTROLLER IS NOT OPERATIONAL, REPLACE THE FAILED CONTOLLER BEFORE UPDATING SOFTWARE (SEE REPLACE CONTROLLER CARD ON page 16-3).

IF THERE IS ONLY ONE CONTROLLER CARD IN THE SYSTEM, SEE UPDATE SOFTWARE VIA XMODEM (ONE CONTROLLER) ON page 17-18.

17-6

August 2003

Access Navigator - Release 1.8

Page 440
Image 440