Electrical Installation

Start RS-232 Management Session

Start RS-232 Management Session

NOTE: Security – No names or passwords are required for new installation and initial turn up. The Access Navigator will accept any user, until password security is turned on.

NOTE: Command Line Interface – The Access Navigator operating system provides a Command Line Interface (CLI), which uses simple text based commands and messages. See Command Line Interface Conventions on page 7-3for a short description of the conventions used in this manual to represent management commands, settings, and messages. For additional information, see CLI Language Reference on page 18-1.

1.Configure computer terminal emulation software, or craft terminal, as follows:

Terminal emulation: ANSI, ASCII, VT100

Flow control: None

Send mode: echo characters locally

Baud rate: 9600

Data bits: 8

Parity: None

Stop bits: 1

NOTE: In the following step, it is only important that the Access Navigator respond with a message. A typical message includes the name of the unit, the time and date, and a prompt.

2.Initiate RS-232 management session by pressing keyboard Enter or Return key.

Carrier Access Corporation Access Navigator

08:30:45 01/30/1999

Access Navigator>

Requirement: Access Navigator message appears on computer or craft terminal display.

NOTE: If there is no response from the Access Navigator, refer to Diagnostics & Troubleshooting on page 15-1.