Alarm Clearing

Minor Alarm Status LEDs

Minor Alarm Status LEDs

A minor alarm means that a non-service affecting condition exists, or that a condition exists affecting service to few customer lines (2 to 23) or has the potential to affect traffic, or that a protection switch occurred. Minor faults include:

￿￿IDLC link failure (primary or secondary EOC/TMS fails) if backup is active ￿￿IDLC link out of service because of loopback test

￿￿Standby Controller card removed or failed ￿￿Self-test failure (in redundant system) ￿￿Power input -48V missing or too low

Table 14-13. Minor Alarm Status LEDs

LED State

Description

Troubleshooting

Off

No minor alarms present

Alarms appear only on the active

 

 

Controller.

 

 

 

Yellow

Minor alarm exists

Use the state of the Power LEDs, Active/

 

 

Standby status LEDs, and DS1 status

 

 

LEDs to help locate the source of the

 

 

fault.

 

 

 

Alarm Cutoff (ACO) Status LED

The Alarm Cutoff feature permits the operator to temporarily silence the alarm outputs while testing and repairing the Access Navigator. ACO does not stop DS1 alarm messages.

Pressing the ACO pushbutton switch disables the alarm relays and lights the ACO status LED. This keeps the relay contacts open on the Alarm Output connector. If another alarm occurs, the alarm relays will be enabled again and the ACO status LED will go off.

Alarm Cutoff disables the following signals on the Alarm Output connector:

￿￿Critical alarm ￿￿Major alarm ￿￿Minor alarm

Table 14-14. Alarm Cutoff (ACO) Status LEDs

LED State

Description

Troubleshooting

Off

Alarm(s) active

Normal operation. Any alarms will

 

 

produce relay closures on the Alarm

 

 

Output connector.

 

 

 

Yellow

Alarm(s) suppressed

ACO disables the alarm relays so that all

 

 

contacts remain open on the Alarm

 

 

Output connector.

 

 

 