Alarm Clearing

Clear Alarms – EOC

Table 14-6 EOC Minor Alarm Message and Trouble Clearing Procedure

Event Message

Description

Trouble Clearing Procedure

Controller A/B

Event Report Replaceable Unit

Remove the standby controller and

Incompatible

Mismatch. Controllers do not

replace with a compatible

 

support the same functionality; for

controller (see Replace Controller

 

example, one supports EOC/TMC

Card on page 16-3) or update

 

and the other does not.

controller with compatible

 

 

software (see Update Controller

 

 

Card Software on page 17-1).

 

 

 

Controller A/B Removed

Event Report Replaceable Unit

Insert a good controller card into

 

Missing. Upon removal the

the empty slot

 

controller card (A or B), the

 

 

remaining controller card is now

 

 

active.

 

 

 

 

Controller A/B software

Event Report Replaceable Unit

Update offending controller with

version mismatch

Mismatch. Controller card

appropriate software (see Update

 

software versions do not match.

Controller Card Software on

 

 

page 17-1).

 

 

 

DS1 n Major Line CV

DS1 is receiving Line Code

Correct the problem with the

 

Violations at a rate greater than

incoming DS1 signal, or provision

 

1.0 x 10-3. This indicates a weak

the DS1 as out of service

 

signal or faulty wiring.

 

 

 

 

EOC Primary/Secondary

Event Report Service Problem.

Check status of DS1 assigned for

Link Down

EOC LAPD data link

EOC with the following CLI

 

communication not established

command:

 

with the switch. Access Navigator

status eoc

 

periodically retries to establish

Check EOC provisioning with the

 

LAPD data link with the switch.

 

Ensure DS1 assigned to EOC is

following CLI command:

 

healthy.

show eoc

 

 

Use following CLI command to

 

 

change setting:

 

 

set eoc <primary/secondary> ds1

 

 

<n>

 

 

 

Remote Device #n:

Remote device on DS1 #n

Clear trouble at remote device.

T1 #x Loss of Synch

reported loss of synchronization

 

 

on T1 #x. Minor alarm for active

 

 

crossconnects.

 

 

 

 

Remote Device #n:

Remote device on DS1 #n

Clear trouble at remote device.

T1 #x rx AIS

received Blue alarm (AIS) on T1

 

 

#x. Minor alarm for active

 

 

crossconnects.

 

 

 

 

Access Navigator - Release 1.8

August 2003

14-11

Page 331
Image 331
Carrier Access Access Navigator user manual Active