CLI Language Reference

CLI Command List

Set Alarms

Purpose: Allows the user to test the Access Navigator alarm functions by manually setting a critical, major, or minor alarm state.

NOTE: Turning alarms on or off will produce alarm messages and log entries stating that the alarm event was manually set or cleared by the user. Manually set alarms are not reported over the GR-303 EOC link to the switch.

Security: Level 2 (operator)

Syntax: set alarms <criticalmajorminor> <onoff>

Field

Description

 

 

critical

Select critical alarm

 

 

major

Select major alarm

 

 

minor

Select minor alarm

 

 

on

Activate manual alarm

 

 

off

Deactivate manual alarm

 

 

Example: set alarms major on

Lights the major alarm LED on the front panel and closes the contacts on the major alarm relay output.

Set Autoexit

Purpose: This command adds a settable timeout that can be enabled or disabled for each supported CLI session. The Access Navigator can have up to three active CLI sessions at the same time, one via RS-232 and two via Telnet. When enabled, the CLI session will automatically expire if there is no user activity during the specified time period. This feature enhances system security by ensuring that the session will be closed if the user forgets to log off. To disable the feature and prevent a timeout from occurring, enter zero as the time.

Security: Level 2 (operator)

Syntax: set autoexit <minutes>

Field

Description

 

 

minutes

Timeout period, 1 to 255 minutes. Enter 0 to disable timeout.

 

 

Example: set autoexit 60

Access Navigator - Release 1.8

August 2003

18-95