Update Controller Card Software

Information and Materials Required

Information and Materials Required

Obtain the following items.

￿Office records for installation site

￿User name (if required)

￿Password (if required)

￿Update software file for Controller

Verify Equipment Status

1.If you are not currently logged into the Access Navigator, start an RS-232 management session.

2.Verify current Controller status and software version with following command:

status equipment

A message similar to the following will appear, showing the Controller cards installed and the software version.

Equipment

Status

Version

---------

------

-------

Controller A

Active

01.77

Controller B

Card not installed

1

DS1 Card 1

Installed

DS1 Card 2

Installed

1

DS1 Card 3

Installed

1

DS1 Card 4

Installed

1

DS1 Card 5

Installed

1

DS1 Card 6

Installed

1

DS1 Card 7

Card not installed

1

DS1 Card 8

Card not installed

1

 

 

 

Active

Standby

SW Build Number

------

-------

17701

 

Boot

Code

Revision

01.09

 

FPGA

Code

Revision

1.06

 

Requirement: Controller is “Active”.

Requirement: Controller shows old software version.

WARNING! DO NOT CONTINUE THIS PROCEDURE IF THE CONTROLLER VERSION IS

01.70UP TO AND INCLUDING 01.80 OR IF THE BOOT CODE REVISION IS 01.07 OR

01.08.USE THE UPGRADE PROCEDURE IN PRODUCT TECHNICAL NOTE PTN-03-004,AVAILABLE BY CALLING CARRIER ACCESS CUSTOMER SUPPORT AT (800) 495-5455.

Access Navigator - Release 1.8

August 2003

17-19

Page 453
Image 453