CLI Language Reference

CLI Command List

Message: Waiting for pattern sync........ok.

 

 

Testing line...

BE:0

CRC:0

BPV/LCV:0

08:15:47

FBE:0

08:15:48

FBE:0

BE:0

CRC:0

BPV/LCV:0

08:15:49

FBE:0

BE:0

CRC:0

BPV/LCV:0

08:15:50

FBE:0

BE:0

CRC:0

BPV/LCV:0

08:15:51

FBE:0

BE:0

CRC:0

BPV/LCV:0

08:15:52

FBE:0

BE:0

CRC:0

BPV/LCV:0

08:15:53

FBE:0

BE:0

CRC:0

BPV/LCV:0

08:15:54

FBE:0

BE:0

CRC:0

BPV/LCV:0

08:15:55

FBE:0

BE:0

CRC:0

BPV/LCV:0

08:15:56

FBE:0

BE:0

CRC:0

BPV/LCV:0

FBE:

Totals

Error Rates

 

0

0.000000e+00

 

BE:

0

0.000000e+00

 

CRC:

0

0.000000e+00

 

LCV/BPV:

0

0.000000e+00

 

Signaling done.

The following error message will occur if an incorrect pattern is received:

Message: Waiting for pattern sync

no sync.

The following error message will occur if there is no loopback in effect:

Message: *-Unable to send code;

*- far-end is not in loopback.

Description:

Item

Description

 

 

Time

Time is recorded in one-second intervals. Format is 24-hour

 

clock in hours:minutes:seconds with colons to separate the digits,

 

as in 08:30:45 and 15:22:10.

 

 

FBE

Number of Frame Bit Errors (4095 maximum) in one-second

 

interval.

 

 

BE

Number of Bit Errors (4095 maximum) in one-second interval

 

 

CRC

Number of Cyclical Redundancy Check errors (1023 maximum)

 

in one-second interval

 

 

BPV/LCV

Number of Bi-Polar Violations and Line Code Violations

 

(16,383 maximum) in one-second interval

 

 

Totals

Total number of errors for 10-second test interval

 

 

Access Navigator - Release 1.8

August 2003

18-69

Page 525
Image 525
Carrier Access user manual Access Navigator Release August 18-69