Electrical Installation

Wire Alarm Input Connector

NOTE: Figure 6-21shows the alarm input connector wiring to a typical alarm interface circuit. The facility alarm input to the Access Navigator should provide normally open contacts. The Access Navigator will energize these wires so that a contact closure will produce a minor alarm indication and minor alarm message.

Input Alarms

1 2 3

Input Alarm Connector on back panel

Alarm Input Circuit

MAXIMUM OUTPUT 24 VDC open circuit

10 mA closed circuit

CABLE SHIELD

MAXIMUM LENGTH Loop resistance of cable must be less than 8 ohms

Alarm input produces minor alarm event tagged with input number

Facility Alarm System

1 2 3 Alarm Sensors

Daisy-chain additional

Alarm Sensors

Figure 6-21. Typical Connections to Facility Alarm System

Access Navigator - Release 1.8

August 2003

6-33

Page 137
Image 137