Alarm Clearing

Clear Alarms – FDL

Table 14-3 CLI Minor Alarm Message and Trouble Clearing Procedure

Event Message

Description

Trouble Clearing Procedure

TMC Primary/

TMC LAPD data link

Check status of DS1 assigned for

Secondary Link Down

communication not established

TMC with the following

 

with the switch. Access Navigator

command:

 

periodically retries to establish

status tmc

 

LAPD data link with the switch.

Check TMC provisioning with the

 

Ensure DS1 assigned to TMC is

 

healthy.

following command:

 

Note: This alarm will also occur if

show tmc

 

TMC or EOC is set to none.

Use following command to change

 

 

 

 

setting:

 

 

set tmc <primary/secondary> ds1

 

 

<n>

 

 

 

Access Navigator - Release 1.8

August 2003

14-7

Page 327
Image 327
Carrier Access Access Navigator user manual Status tmc, Show tmc