![5 Cavity offset calibration (for lev. A and C ovens)](/images/new-backgrounds/176305/17630515x1.webp)
Electrolux Professional S.p.A.
Ovens Platform Customer Support
Technical Training & Service
AOS_Q OVENS – Service manual
(593804600 - ENG)
1.The calibration was not done correctly. The cavity was not completely dry. Do it again.
2.An electric/electronic problem. Please verify the follow:
•230V AC at the input of the lambda switching feeder
•approximately 9.5V DC at the feeder’s output
•approximately 9.5V DC at the lambda input (if not, verify the cable integrity)
•an output from the lambda in the range of
•same value at the PCB input (connector X23). If there is no signal please verify the cable integrity
•if the above conditions are respected and the value stored in the parameter OLbd is still out of the correct range, the problem is in the PCB.
5 Cavity offset calibration (for lev. A and C ovens)
In order to adjust the offset of the cavity probe, enter in parameter programming and set parameters cort and OCA1 to 0.
Then run a steam cycle for several minutes and check the cavity temperature, which should stabilize at the water boiling point. If the stabilized cavity temperature is less or greater than the correct water boiling pointFPT2FPT, a corrective value can be stored in parameter OCA1.
After this, set parameter cort to 1and set parameter SEAL (altitude above sea level).
6 Error codes
Errors can be divided into 2 categories: errors (they stop the appliance) and warnings (they do not stop the appliance).
6.1Errors
EE2P: Communication error with the EEPROM
EtUC: Cavity over temperature; cavity temperature exceeded value stored in parameter cot.
EtUB: Boiler over temperature; boiler temperature exceeded value stored in parameter bot.
EFUN UP/DOWN: Activation of the thermal protection of the motor. On the little temperature display it will appear “UP” or “DOWN” according it is the thermal protection of the upper motor (and the motor of
Etc: Tripping out of cavity limiter
Etb: Tripping out of boiler limiter
ESCH: Over temperature on the electronic board; check the cooling fan and the ventilation openings on the bottom of the control panel.
Ept1: cavity probe in open circuit (only the steam cycle – 100 °C can be selected)
Ept2: boiler probe in open circuit (only hot air cycle can be selected)
Ept3: meat probe in open circuit (only time cooking can be selected)
Ept4:
Ept8: NTC probe in short or open circuit
ECAD: Analogic/Digital converters not working (thermocouples input signal)
Ertc : No communication with the clock. On lev. C set parameter Ertc to zero
E PM: Communication error with PWM system (only gas versions)
E SL: Water level probe error (probes in short circuit). If the boiler heating elements or burners are on for a time over that one defined in parameter tbon without a water charging phase, this error message is activated. To reset it, parameter ALFn has to be reset to 0.
2PT TP See Appendix A