Electrolux AOSQ OVENS - Service manual 593804600 - ENG, ƒ gas valve from SIT type SIGMA

Models: 593804600

1 31
Download 31 pages 7.14 Kb
Page 14
Image 14
ƒgas valve from SIT type SIGMA 848

Electrolux Professional S.p.A.

Ovens Platform Customer Support

Technical Training & Service

AOS_Q OVENS – Service manual

(593804600 - ENG)

The gas system is made with CO and NOx low emission burner. The main components are the following:

ƒgas valve from SIT type SIGMA 848

ƒAC burner blower that is intaking air through a calibrated mixer where the air–gas mixture is created; then the fun conveys the mixture to the burner

ƒA cavity and a boiler heat exchanger made with a corrugated tube for increasing the efficiency

ƒAn ignition rod and a detection rod

ƒA flame control device

ƒAn external igniter

Starting a cooking cycle, the POW board of the oven activates the flame control device and the burner fan whose speed is controlled with a PWM signal.

The POW board activates the flame control device. From pin 8 of this device a high voltage output (230 Vac) is carried to the relevant burner fan and to the high voltage digital input section of the POW board (X10/5÷8). With an high voltage input on X10/5÷8, the POW board generates on X9/2÷5 a PWM signal to control the speed of the burner fans (a signal that defines the rotating speed of he fan and so the quantity of sucked air and gas) and the 12 Vdc on X9/1 to feed the inner board of the burner fan. The PWM signal changes according to the status of the burner, i.e.:

ƒStart of the burner: controlled with parameters StcA (start of cavity burners) and Stbo (start of boiler burners).

ƒFull power of the burner: controlled with parameters FucA (full power of cavity burners) and Fubo (full power of boiler burners)

ƒHalf power of the burner: controlled with parameters hAcA (half power of cavity burners) and hAbo (half power of boiler burners)

The quantity of sucked gas is controlled with those parameters (which are determining the speed of the burner fans), with the injector/diaphragm inserted at the outlet of the gas valve and with the calibration of the offset value on the gas valve.

The quantity of sucked air is controlled with the above parameters and with the calibrated aerator on the mixer.

The ignition sequence is then the following:

The POWER board activates the flame control device

After 1.5 s, the control device activates the fan that start at the speed determined with parameters Stxx

The flame control device activates the external igniter through pin 14, the igniter generates the spark for 2s and after these, there are 2 s for flame detection

If the flame is detected, the start speed is maintained for around 10 s and after this time the fans are carried to their working speed (half or full power)

If the flame is not detected, the fan keep on running for an inter purge phase of 15 s; after this phase there is a stop of the fan for 1 s and the ignition sequence is repeated. If the flame is still not detected there will be again 15 s of purging phase and this for five times before the lockout signal.

In case of loosening of the flame signal during working, only one re-ignition attempts takes place.

So if the burner fan is off for at least 0.5 s (the fan is controlled from the flame control device through the 230Vac signal form pin 8), the POW board deduces that the flame control device is going to try again an ignition sequence and then goes back to the beginning of the ignition sequence. If on the contrary the burner fan is off for at least 5 s, the POW board deduces that the flame control device is in lockout.

In case of conversion to different type of gas, besides the injector/diaphragm also the parameters, which control the PWM signal, and the offset pressure calibration have to be changed according to the gas calibration table

NB: In case of changing from natural gas to LPG or G30 in some models, the fan flange (fig. 24) has to be changed; these changes has to be made in

CAVITY burner of 10 2/1 e 20 2/1 ovens

BOILER burner of 10 1/1, 10 2/1 e 20 1/1 ovens

File: AOS ONE service manual (ENG).01.doc ©Copyright 2007 by Electrolux Professional