13.2 Offeset pressure calibration

Electrolux Professional S.p.A.

Ovens Platform Customer Support

Technical Training & Service

AOS_Q OVENS – Service manual

(593804600 - ENG)

- +

Offset adjustment screw

Offset pressure test point

Fig. 23 - Injector

Fig. 24 – burner flange

13.2 Offeset pressure calibration

For the adjustment of the offset pressure, connect a manometer with a resolution of 1 Pa (100 Pa=1 mbar) to the offset pressure test point after loosening the sealing screw. To adjust the cavity gas valve offset, set a hot air cycle, half power; to adjust the boiler gas valve offset select a steam cycle, half power. Wait around 3 minutes for the stabilization of the pressure before adjusting it turning slowly the screw indicated in the picture above.