AOS_Q OVENS – Service manual
(593804600 - ENG)
Nome | Descrizione | |
hAbo | PWM value at middle power of boiler burners | |
HabP | Steam condenser engagement in "hot air" mode | |
hAcA | PWM value at middle power of cavity burners | |
hAir | Hot air hour counter | |
hboL | Boiler hour counter | |
HbYP | Max humidity value to stop the boiler | |
HCCP | HACCP Mode | |
hcMb | Combi hour counter | |
Hdut | Flag to enable heater duty cycle (0=disable; 1=enable) | |
hHEA | Delay on burner flame ignition after the start of the cavity motor | |
hStM | Steam hour counter | |
Huon | ON phase of the humidifier with combi cycle beetween 50 and 100 degrees | |
LAMb | Presence of lambda probe (1=yes) | |
LanG | Language for the menu | |
Man | Flag to enable manual cookings (0=disable; 1=enable) | |
nMod | Define if the modification of store program is disable | |
OCA1 | OFFSET of first cavity probe | |
0lbd | Calibration of the lambda probe (0% of humidity) | |
PASS | Flag to enable password (0=disable, 1=enable) | |
PAUT | Flag to enable special programs, i.e. preheating programs and Low temperature | |
(0=disable; 1=enable) | ||
| ||
PFAC | Flag to enable factory preset recipes (0=disable; 1=enable) | |
PPM | Flag to enable Peak Power Management (0=disable; 1=enable) | |
PrEH | Flag to enable cavity preheating during cooking (0=disable; 1=enable) | |
Sbc | Cooling temperature set for board ventilation | |
SbYP | Bypass temperature with max. cooking cavity steam temperature (calibration) | |
SEAL | Altitude above sea level | |
SinC | Boiler temperature that detect presence of scale | |
SPHb | Preheating temperature of the boiler | |
SPHF | Boiler temperature during leavening | |
Stbo | PWM value at start of boiler burners | |
StbP | Steam condenser engagement in "boiler" mode | |
StcA | PWM value at start of cavity burners | |
StoF | Minimum time for "switch off" of boiler | |
Ston | Minimum time for "switch on" of boiler | |
tbon | Timeout for E SL alarm, water level probe alarm | |
tcdb | Max water temperature for boiler drain | |
tCMS | Limit of cavity temperature set for working at high temperature | |
thMA | Define the max. temperature limit for the manual injection of water | |
tPrn | Print frequency (0=no print) | |
trMA | Define the max. temperature for water injection during cooling phase | |
trMn | Define the min. temperature for water injection during cooling phase |