FDL Interface

 

 

Access Bank II Capabilities

 

 

 

 

Access Bank II Capabilities (Continued)

 

 

 

 

Interface

Capabilities and Settings

 

 

 

 

RS-232 interface

Asynchronous RS-232 port for subrate data

 

 

connection between two Access Bank II terminals

 

 

Assignable to one DS0

 

 

Baud rate: 1200, 2400, 4800, 9600, 19200, 38400,

 

 

57600

 

 

Data bits: 7, 8

 

 

Start bits: 0

 

 

Stop bits: 1, 2

 

 

Parity: None, Even, Odd

 

 

Receive clock: Internal, External

 

 

Loopback: line

 

 

 

 

SDSL interface

High-speed data port for SDSL router

 

 

Data rates up to 1.024 Mbps

 

 

Assignable to a group of up to 16 DS0s

 

 

SDSL port replaces T1 #2 port on Access Bank II/

 

 

SDSL

 

 

 

 

T1 Drop interface (T1 #1 or #2)

Drop and insert port for T1 PBX

 

 

High-speed data port for T1 router

 

 

Assignable to a group of one or more DS0s

 

 

DS0s on T1 drop are assigned sequentially, starting

 

 

with DS0 #1

 

 

Framing: D4 (SF), ESF

 

 

Line code: AMI, B8ZS

 

 

Line build out: 0 to 666 feet, 0 to –22.5 dB

 

 

Loopback: line, payload

 

 

 

 

V.35 interface

High-speed data port for network router connection

 

 

Assignable to a group of one or more DS0s

 

 

Data speed (Kbps): Nx56 or Nx64, where N is the

 

 

number of DS0s assigned

 

 

CTS: Force High, Force Low, Follow CD, Follow

 

 

RTS

 

 

Rx timing: Internal, External

 

 

Clock inversion: None, Rx, Tx, Rx and Tx

 

 

Data inversion: None, Invert

 

 

V.54 Data Service Unit (DSU) loopcode detection:

 

 

on, off

 

 

 

Access Navigator - Release 1.8

August 2003

B-5

Page 657
Image 657