Carrier Access Access Navigator EOC Warning Alarm Message and Trouble Clearing Procedure, Switch

Models: Access Navigator

1 704
Download 704 pages 57.28 Kb
Page 333
Image 333

Alarm Clearing

Clear Alarms – EOC

Table 14-7 EOC Warning Alarm Message and Trouble Clearing Procedure

Event Message

Description

Trouble Clearing Procedure

Alarm Count List

Event Report Service Problem.

The alarm is cleared after all

Change

(Reported only if the alarm count

events reportable to the switch

 

list has been created. The alarm

have been cleared.

 

count list is created by DMS

 

 

switches.)

 

 

The number of alarms active in the

 

 

Access Navigator has changed.

 

 

Only those alarms reportable to

 

 

the switch and excluding Service

 

 

Problems are included in the alarm

 

 

count list.

 

 

 

 

Analog Line

Event Report Service Problem.

Correct the problem with the

Termination Out of

A previously in-service DS0

incoming DS1 signal, or provision

Service

configured as an analog line

the DS1 as out of service.

 

termination has been disabled

 

 

(set ds0 <n:ch> down) or an

 

 

error condition has been detected

 

 

and the DS1 is now out of service.

 

 

 

 

DS1 Out of Service

Event Report Service Problem

Correct the problem with the

 

(Reported only if DS1 type =

incoming DS1 signal, or provision

 

SWITCH).

the DS1 as out of service.

 

A previously in-service DS1 has

 

 

been disabled (set ds1 <n>

 

 

down) or an error condition has

 

 

been detected and the DS1 is now

 

 

out of service.

 

 

 

 

System Alarm State

Event Report Service Problem

The alarm is cleared after all

Change

(5ESS only).

events reportable to the switch

 

The severity of the system alarm

have been cleared.

 

state has changed. Only those

 

 

events reportable to the switch and

 

 

excluding Service Problems are

 

 

included in the system alarm state.

 

 

 

 

Access Navigator - Release 1.8