Start Management Session

Obtain Information

Obtain Information

NOTE: User names and passwords are not required until security features are activated.

Obtain office records with the following information:

User name (if required)

Password (if required)

Connect RS-232 Cable to Access Navigator

1.If you already have an RS-232 cable connection to the Access Navigator, go to step Step

2.Connect RS-232 DCE-to-DTE cable with 9-pin DE9 (DB9) connector on one end to RS-232 CLI management connector on rear panel of Access Navigator (see Figure 7-1).

3.Connect other end of RS-232 cable to computer or craft terminal.

DS1

Receive

IN

Timing

In

DS1

Transmit

Alarm Out

-48V

B

OUT

Alarm

In

Ethernet

Link OK

-48V

A

RS-232

CLI

RS-232 CLI

Management

Connector

Figure 7-1. Location of RS-232 CLI Connector

Set Up Terminal Program

Configure computer terminal emulation software, or craft terminal, as follows:

Terminal emulation: ANSI, ASCII, or VT100

Flow control: None

Send mode: Echo characters locally

Baud rate: 9600

Data bits: 8

Parity: None

Stop bits: 1

Access Navigator - Release 1.8

August 2003

7-5

Page 175
Image 175
Carrier Access user manual Obtain Information, Connect RS-232 Cable to Access Navigator, Set Up Terminal Program