Alarm Clearing

Clear Alarms – SNMP

Clear Alarms – SNMP

NOTE: This procedure describes Access Navigator trap messages sent to a Network Management System (NMS) IP address. If Command Line Interface (CLI) commands are needed to clear the alarm, the operator should go to Clear Alarms – FDL on page 14-3.

1.Retrieve trap messages from the network management system.

2.If there are any trap messages, follow trouble clearing procedure in Table 14-8to clear alarms and then return to Step 1.

Table 14-8 Trap Message and Trouble Clearing Procedure

Trap Message

Description

Trouble Clearing Procedure

authenticationFailure

Occurs when a bad community

None required. However, repeated

 

string is used.

occurrences may indicate an

 

 

incorrect management program

 

 

setting or an attempt to breach

 

 

security.

 

 

 

linkDown

Sent when a DS1 changes from an

Message includes DS1 number (1

 

up (in service) state to a down (out

to 32). To clear the DS1 alarm, see

 

of service) state. It is not sent

Clear Alarms – FDL on

 

when a DS1 is set “down” by a

page 14-3.

 

CLI command.

 

 

 

 

linkUp

Sent when a DS1 changes from a

None required.

 

down (out of service) state to an

 

 

up (in service) state. It is not sent

 

 

when a DS1 is set “up” by a CLI

 

 

command.

 

 

 

 

warmStart

Sent whenever the SNMP agent is

None required. However, if not

 

restarted as a result of a software

caused by operator, then repeated

 

reset or unit power-up.

occurrences may indicate a facility

 

 

power problem.

 

 

 

14-14

August 2003

Access Navigator - Release 1.8