Provision Remote Adit 600 via IP DS0

Obtain Provisioning Information

Obtain Provisioning Information

1.Obtain office records for installation site.

2.Obtain circuit orders for remote Adit 600 service turn up.

Verify Equipment Configuration

CAUTION! VERIFY CURRENT CONFIGURATION AND SERVICE STATUS WITH OFFICE RECORDS BEFORE ADDING, DELETING, OR CHANGING CIRCUITS.

NOTE: The factory default sets all DS1s and DS0s in-service (up). To prevent inadvertent service disruptions, it is good practice to set circuits out of service (down) when not in use or not provisioned in the switch. Set the type of unused DS0 channels to match the DS0 type configured on the device at the other end of the DS1. If the DS1 is not terminated, set the type to data.

1.Start management session (see Start Management Session on page 7-1).

2.Verify number of DS1 circuits installed by comparing equipment status with office records with the following command:

status equipment

A message similar to the following will appear, showing the equipment card slots, service status, and Controller software version.

Equipment

Status

Version

---------

------

-------

Controller A

Active

01.70 GR-303 Option

Controller B

Standby

01.70 GR-303 Option

DS1 Card 1

Installed

1

DS1 Card 2

Installed

1

DS1 Card 3

Installed

1

DS1 Card 4

Installed

1

DS1 Card 5

Installed

1

DS1 Card 6

Installed

1

DS1 Card 7

Card not installed

DS1 Card 8

Card not installed

3.Verify number of DS1 circuits installed by comparing equipment status with office records. If there is a discrepancy, follow standard practices to resolve problem.

4.Show current DS1 service status with the following command:

show ds1 all

13-8

August 2003

Access Navigator - Release 1.8

Page 304
Image 304
Carrier Access Access Navigator user manual 13-8