CLI Language Reference

CLI Command List

Message:

Alarms:

 

 

Current

Accumulated

 

 

 

 

sys power

 

 

-------

-----------

 

 

off

off

sys brownout

 

off

off

sys redun

 

 

off

off

sys reset

 

 

off

off

v35 rts

 

 

off

off

v35 llb

 

 

off

off

v35 v54

 

 

off

off

t1

(T1#1)

carrier

off

off

t1

(T1#1)

csuloop

off

off

t1

(T1#1)

unframed

off

off

t1

(T1#1)

sync

 

off

off

t1

(T1#1)

yellow

off

off

t1

(T1#1)

bpv

 

off

off

t1

(T1#1)

ses

 

off

off

t1

(T1#1)

unavail

off

off

t1

(T1#1)

fdlline

off

off

t1

(T1#1)

fdlpay

off

off

t1drop (T1#2)

carrier

off

off

t1drop (T1#2)

csuloop

off

off

t1drop (T1#2)

unframed

off

off

t1drop (T1#2)

sync

off

off

t1drop (T1#2)

yellow

off

off

t1drop (T1#2)

bpv

off

off

t1drop (T1#2)

ses

off

off

t1drop (T1#2)

unavail

off

off

t1drop (T1#2)

fdlline

off

off

t1drop (T1#2)

fdlpay

off

off

Item

Description

 

 

Current

Indicates current alarm state

 

 

Accumulated

Indicates if any alarms have occurred (accumulated) since the

 

last time the alarm status was read. This flag is cleared (set to

 

“off”) after reading.

 

 

off

No alarms occurred

 

 

on

One or more alarms occurred

 

 

sys power

Hard reset or power-on detected

 

 

sys brownout

Low input power (–48 VDC input) detected

 

 

sys redun

Redundant T1 switch occurred

 

(This feature is not supported by the Access Navigator)

 

 

sys reset

Soft reset detected

 

 

18-46

August 2003

Access Navigator - Release 1.8

Page 502
Image 502
Carrier Access Access Navigator user manual 18-46