Carrier Access Access Navigator user manual Set DS1 Clock, Set DS1 FDL

Models: Access Navigator

1 704
Download 704 pages 57.28 Kb
Page 562
Image 562

CLI Language Reference

CLI Command List

Syntax: set ds0 <n:ch> type <datavoicegr303>

Field

Description

 

 

n

DS1 number, 1 to 32.

 

 

ch

DS0 number, 1 to 24, or a range of numbers such as 5-8.

 

 

data

Set DS0 to carry DCS data traffic.

 

 

voice

Set DS0 to carry DCS voice traffic.

 

 

gr303

Enable DS0 to carry GR-303 voice traffic. (ISDN BRI 4:1 TDM

 

mode circuits are automatically assigned as gr303 type.)

 

 

Example: set ds0 2:3 type data

Example: set ds0 2:12 type voice

Example: set ds0 13:1-16 type gr303

Set DS1 Clock

Purpose:

Sets the transmit clock source for the specified DS1 interface.

Security:

Level 2 (operator)

Syntax:

set ds1 <n> clock <normalloop>

Field

n

normal

loop

Description

DS1 number, 1 to 32, or a range of numbers such as 2-8.

Set to master transmit clock source.

Set clocking for this DS1 to clock recovered by DS1 receiver. (Should not be used during normal operation.)

Example: set ds1 9 clock normal

Example: set ds1 1-12 clock normal

Example: set ds1 9 clock loop

Set DS1 FDL

Purpose: Selects the FDL protocol used on drop DS1s. Switch and groom DS1s do not use FDL. The Facility Data Link (FDL) channel is a 4 Kbps out-of-band communications link provided by the DS1 Extended Superframe (ESF) format.

NOTE: The factory default setting is “none”. This also turns off out-of-band loopback code detection and transmission over the FDL channel.