Diagnostics & Troubleshooting

Access Bank II Loopbacks

Access Bank II Loopbacks

NOTE: All read remote and send remote commands require that the remote Access Bank II is operational and connected to an Access Navigator drop DS1 using Carrier Access FDL management protocol.

NOTE: Only one port of the Access Bank II can be looped up at a time. If a loopup command is received for a second port, the first port will be looped down automatically before the second port is looped up.

￿Read Remote Loopback ... 15-36

￿Send Remote Loopdown ... 15-36

￿Send Remote RS232 Line Loopup ... 15-37

￿Send Remote RS232 TSI Equipment Loopup ... 15-37

￿Send Remote RS232 TSI Network Loopup ... 15-38

￿Send Remote SDSL Payload Loopup ... 15-38

￿Send Remote T1 Payload Loopup ... 15-39

￿Send Remote T1 TSI Loopup ... 15-39

￿Send Remote T1 Drop Line Loopup ... 15-40

￿Send Remote T1 Drop Payload Loopup ... 15-40

￿Send Remote V35 Line Loopup ... 15-41

￿Send Remote T1 Drop Line Loopup ... 15-40

￿Send Remote T1 Drop Payload Loopup ... 15-40

￿Send Remote V35 Line Loopup ... 15-41

￿Send Remote V35 TSI Equipment Loopup ... 15-42

￿Send Remote V35 TSI Network Loopup ... 15-42

Read Remote Loopback

Reads and displays the loopback status of the remote terminal on the specified DS1. Used to read status of the following send remote commands.

Syntax: read remote <n> loopback

Send Remote Loopdown

Disables the send remote loopup commands.

Syntax: send remote <n> loopdown

15-36

August 2003

Access Navigator - Release 1.8

Page 378
Image 378
Carrier Access Access Navigator user manual Access Bank II Loopbacks, Read Remote Loopback, Send Remote Loopdown