Diagnostics & Troubleshooting

Send DS1 Line Pattern with BER Test

Access Navigator

Line

Code

Unframed

Pattern

Generator

Pattern

with BERT

 

 

Far End

Line Loopup

Time Slot

Interchange

Framer

Bit Error

Rate

Tester

Line

Interface

Unit

Access Bank II

IN

DS1 OUT CSU

Figure 15-25. Send DS1 Line Pattern with BER Test

Syntax: send ds1 <n> line <p2e11p2e15p2e23qrss> test

Field

Description

 

 

n

DS1 number, 1 to 32, or a range of numbers such as 2-8.

 

 

p2e11

Send 211–1 pattern with a maximum of 10 consecutive zeros and

 

11 consecutive ones. (Minimum stress testing.)

 

 

p2e15

Send 215–1 pattern with a maximum of 14 consecutive zeros and

 

15 consecutive ones. (Provides maximum number of consecutive

 

zeros permissible in framed, non-B8ZS testing.)

 

 

p2e23

Send 223–1 pattern with a maximum of 22 consecutive zeros and

 

23 consecutive ones. (Maximum stress testing.)

 

 

qrss

Send QRSS pattern (a modified 220–1) with a maximum of 14

 

consecutive zeros and 20 consecutive ones. (Common stress test

 

for T1 data applications.)

 

 

Example: set ds1 9 line p2e15 test

The CLI will provide a progress message indicating the success (ok) or failure of the command, as in the following samples.

Message: Waiting for pattern sync........ok.

 

 

Testing line...

BE:0

CRC:0

BPV/LCV:0

08:15:47

FBE:0

08:15:48

FBE:0

BE:0

CRC:0

BPV/LCV:0

Access Navigator - Release 1.8

August 2003

15-47

Page 389
Image 389
Carrier Access Access Navigator Syntax send ds1 n line p2e11p2e15p2e23qrss test, Example set ds1 9 line p2e15 test