Carrier Access Access Navigator user manual Turn Up Service, Test DS1 and DS0 Circuits

Models: Access Navigator

1 704
Download 704 pages 57.28 Kb
Page 213
Image 213

Provision DCS Service

Turn Up Service

Turn Up Service

1.Show current DS1 status with the following command: status ds1 <n>

Example: status ds1 1-32

2.Show current DS0 status with the following command: status ds0 <n:ch>

Example: status ds0 1:1-24

Example: status ds0 8:1-24

3.If drop DS1 and DS0 settings are correct, skip remaining steps.

4.Set DS1s and DS0s to in-service (up) status with the following commands:

set ds1 <n> up set ds0 <n:ch> up

Example:

set ds1

5 up

Example:

set ds0

5:1-6

Test DS1 and DS0 Circuits

NOTE: The Access Navigator supports the following T1.403 loop tests:

Responds to ESF bit patterned loop requests (when loopdetect is on)

Generates ESF bit patterned loop requests

Generates SF CSU inband loopcodes

1.Follow standard practices to test subscriber drop DS1 circuits.

2.Follow standard practices to test DS0 connections.

Access Navigator - Release 1.8

August 2003

9-19