Alarm Clearing

Clear Alarms – FDL

Table 14-3 CLI Minor Alarm Message and Trouble Clearing Procedure

Event Message

Description

Trouble Clearing Procedure

EOC Primary/Secondary

EOC LAPD data link

Check status of DS1 assigned for

Link Down

communication not established

EOC with the following

 

with the switch. Access Navigator

command:

 

periodically retries to establish

status eoc

 

LAPD data link with the switch.

Check EOC provisioning with the

 

Ensure DS1 assigned to EOC is

 

healthy.

following command:

 

Note: This alarm will also occur if

show eoc

 

TMC or EOC is set to none.

Use following command to change

 

 

 

 

setting:

 

 

set eoc <primary/secondary> ds1

 

 

<n>

 

 

 

Manually set minor

Allows user to set and clear

Use following command to clear

alarm

critical alarm state. LED, relay,

alarm:

 

alarm, and event logs follow

set alarms minor off

 

setting.

 

 

 

 

On Board Power Supply

DC power supply on the controller

Reporting controller card (A or B)

A/B Failure

(A or B) caused a failure.

must be replaced.

 

 

 

Remote Device #n: T1

Remote device on DS1 #n

Clear trouble at remote device.

#x Loss of Carrier

reported loss of carrier on T1 #x.

 

 

 

 

Remote Device #n: T1

Remote device on DS1 #n

Clear trouble at remote device.

#x Loss of Synch

reported loss of synchronization

 

 

on T1 #x.

 

 

 

 

Remote Device #n: T1

Remote device on DS1 #n

Clear trouble at remote device.

#x rx AIS

received Blue alarm (AIS) on T1

 

 

#x.

 

 

 

 

Remote Device #n: T1

Remote device on DS1 #n

Clear trouble at remote device.

#x rx Yellow alarm

received Yellow alarm (RAI) on

 

 

T1 #x.

 

 

 

 

Remote Device #n: V.35

Remote device on DS1 #n

Clear trouble at remote device.

loss of RTS

reported loss of RTS on V.35

 

 

interface.

 

 

 

 

14-6

August 2003

Access Navigator - Release 1.8

Page 326
Image 326
Carrier Access Access Navigator user manual Status eoc, Show eoc