Maintenance Procedures

Install SIMM on Controller Card

Eject

A

Card Ejector

Latches E

Lock

SIMM

C

B

SIMM

Socket

Notch

D

SIMM

Socket

Figure 16-16. Installing Controller Card SIMM

NOTE: If status indications are not correct, refer to Diagnostics & Troubleshooting on page 15-1.

9.Verify power-on status of upgraded Controller. The LED indicators should be as follows: Requirement: Upgraded CONTROLLER POWER indicator lights green.

10.Wait two minutes for upgraded Controller to learn system settings.

11.Verify upgraded Controller status by entering the following command:

status equipment

Requirement: Upgraded Controller status is “Standby”.

12. Put upgraded Controller into active mode by entering following command:

16-34

August 2003

Access Navigator - Release 1.8

Page 432